KM9106 Operators Manual34The above example will send the Time and Oxygen reading to the printout every twominutes.To stop the Quintox Auto printing or logging, select Auto print OFF above and returnto the main displays.7.2.1 Standard Printout - Parameter Options Used:LINENUMBERPARAMETERUSED:(MAX LINES: 40) & STATUS:1 - - - - - - - - - - - - PRINTOUT START2 BLANK LINE3 ***KANE-MAY*** MANUFACTURER ID4 **KM QUINTOX** ANALYSER ID5 BLANK LINE6 DATE 02-01-97 DATE7 TIME 18 :14:35 TIME8 BLANK LINE9 NATURAL GAS FUEL SELECTED10 BLANK LINE11 02 % ......20.9 FLUE GAS 02 CONTENT12 CO ppm .....0.0 FLUE GAS CO CONTENT13 Prs mbar ....0.05 PRESSURE MEASUREMENT14 EFF %.....FAULT COMBUSTION EFF CALC15 BLANK LINE16 XAIR O2>20% FLUE GAS EXCESS AIR17 C02 %.......0.0 FLUE GAS CO 2 CALC (CO2m% FLUE GASCO 2 MEASURE)18 CO/CO2 R....0.00 CO/CO 2 RATIO19 PI % .....0.00 POISON INDEX20 NO ppm.....0 FLUE GAS NO CONTENT21 NO2 .....0 FLUE GAS NO 2 CONTENT22 NOx ppm.....0 NOX CALCULATION23 SO2 ppm.....0.0 FLUE GAS S02 CONTENT24 CxHy % ...... 0.0 HYDROCARBON READING25 BLANK LINE26 NETT C 0.0 NET FLUE GAS TEMP27 FLUE C 21.0 ACTUAL FLUE GAS TEMP28 INLT NOTFITTEDBOILER INLET TEMP29 AMBIENT C 16.9 AMBIENT AIR TEMP30 - - - - - - - - - - - - DOTTED LINENot all parameters are used. See the master list on the next page if more are required.