28 English 5.906-591.0 Rev. 00 (01/14)Subject to technical modifications!*The max. flow rate is derived from the measurement with-out the backflow valve installed.No data.When working on the device, please always use the cur-rent circuit diagram in DISIS.Technical DocumentationAppliance type Appliance no. Circuit diagram Operating instruc-tionsSpare parts listK 6.200 1.446-000.01.446-001.00.089-226.0 5.964-673.05.965-054.05.972-214.0K 7.200 1.447-000.01.447-001.00.089-226.0 5.964-673.05.965-054.05.971-607.0K 7 Compact 1.447-002.01.447-003.01.447-004.00.089-226.0 5.965-162.0 5.971-607.0Technical specificationsK 6.200 K 7.200 K 7 CompactElectrical connectionVoltage 2301~50VHzConnected load 2,5 3,0 3,0 kWProtection class IP X5Protective class IMains fuse (slow-blow) 16 AWater connectionMax. feed pressure 0,6 MPaMax. feed temperature 60 °CMin. feed volume 12 I/minMax. Suction height 1,0 mPerformance dataWorking pressure 13 15 15 MPaMax. permissible pressure 15 16 16 MPaWater flow rate 8,8 9,2 9,2 I/minRecoil force of trigger gun 20 22 22 NDetergent flow rate 0 - 0,3 I/minDimensions and weightsLength 552 mmWidth 290 mmHeight 333 mmWeight, ready to operate with accessories 17,0 18,7 19,2 kgValues determined as per EN 60335-2-79Hand-arm vibration valueUncertainty K< 2,50,3m/s2m/s2Sound pressure level L pAUncertainty K pA773dB(A)dB(A)Sound power level L WA + Uncertainty KWA 93 94 93 dB(A)TorquesCircuit diagram