11First Time SetupFirst Time Power Up (Keypad Initialization)After first time power up, Tuxedo steps through the following setup prompts. These options can also beset later using the appropriate menus.Installer Note: The Tuxedo touch-screen has been calibrated at the factory. Ignore the “CALIBRATE”button that appears on the “Options” screen after initial ECP setup. If the screen should requirerecalibration, the end user may do so via the “Keypad Test” screen. See the “Diagnostic Tests” section.Set ECP Address/RIS Automation AddressIf the system is using only one Tuxedo, leave the address set to 1 and press Apply. The boot-up processcontinues until completion. If additional Tuxedo keypads are installed in the system, enable each one byassigning it an address, then power-up each Tuxedo one at a time, and set its address to one of theaddresses enabled in the control panel.If using Remote Services, set the RIS Automation Address to the appropriate RIS address for usingTotal Connect. Select the Primary RIS Device checkbox if this is the primary device to be enabled.IMPORTANT: In order for local Z-Wave scenes to function in automation, your Vista system requires onesystem RIS automation device (keypad or AlarmNet device). If using an AlarmNet Communicator withthe RIS option enabled, uncheck the Primary RIS Device feature in the Tuxedo.Refer to the Control Panel Installation Instructions for additional information.NOTE: The Tuxedo ECP address (1-30) is defaulted to 1; the RIS Automation address (1-30) isdefaulted to 25. The ECP & RIS addresses can also be set later using the ECP Address menufrom the CS Setup menu.NOTES:1. If “ECP Error” is displayed, the ECP address in the keypad is not valid for the panel that it isconnected to. In this case, to change the ECP Address, enter the default code of “4140” to advance tothe next screen.2. Default code “4140” is the Tuxedo default installer code before connecting to a control panel. Onceconnected to a control panel, use that panel’s installer code.To change the address, perform the following:From the "Home" screen, press the Setup icon and then the System setup icon.Press the CS Setup icon and enter your Authorized Code, if required.Press the ECP Address123 icon. Select the ECP address for this keypad using the Up/Dn arrows.The available ECP addresses are:1-2, 5-6: for VISTA Plus series controls1-2, 3-30: for older commercial controls under Rev. 10 supports 3 AUIs.*See Important Note below.1-30: for VISTA Turbo series controls Rev. 10 and higher supports 6 AUIs.*IMPORTANT: If multiple keypads are being used, they must be set to addresses 1, 2, and X (where Xequals any address from 3 through 30). Only one AUI type device may be assigned to an address from 3through 30 on commercial control panels.NOTES:1. When Tuxedo cannot communicate with the alarm panel, the message “ECP Error” is displayed,check the following: