Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Section 1: Quick Setup
- Section 2: System Operation
- Direct Access
- Exiting from Engineer Mode
- Multi User Access
- Section 3: Setting Options
- Unsetting the System
- Card Setting Options
- Setting Features
- Omitted Zones
- Abort Time
- Section 4: Menu Options 11-19
- Option 12 – Timed Set
- Option 17 – Instant Part
- Section 5: Display Options
- Option 22 – Display Log (Quick Menu Option 4)
- Option 23 – System (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 24 – Print (Quick Menu Option 5)
- Option 25 – Access Doors
- Section 6: Test Options
- Option 32 – Outputs
- Section 7: Modify Options
- Option 42 – Codes (Quick Menu Option 8)
- Default Codes
- Escaping from Engineer Mode
- Programming Codes
- Option 43 – Summer (Quick Menu Option 9)
- Option 45 – Timer Control (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 46 – Group Omit (Galaxy 18, 60, 128, 500 & 504)
- Option 47 – Remote Access
- Option 48 – Engineer Access (Galaxy 512 only)
- Option 49 – Datelock (Galaxy 512)
- Section 8: Engineer 1
- Option 52 – Program Zones
- System Alarms
- Option 53 – Program Outputs
- Attributes
- Output Functions
- Option 54 – Links (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 55 – Soak
- Option 56 – Communications
- Telecom Module
- RS232 Interface Module
- ISDN Module
- Ethernet Module
- Option 57 – System Print
- Option 58 – Keypad
- Option 59 – Quick Menu
- Section 9: Engineer 2
- Option 62 – Full Test (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 63 – Options (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 64 – Assemble Zone (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 65 – Timers (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 66 – Pre-checks (Galaxy 60, 128, 500, 504 & 512)
- Option 67 – Remote Reset
- Option 68 – Menu Access (Galaxy 60, 128, 500, 504 & 512)
- Appendix A : Door Control - MAX (MX01)
- Mounting the MAX
- Configuring a MAX Reader into the System
- Configuring as On-Line MAX
- Removing a MAX Reader from the System
- Operating Instructions (On-Line Modes)
- Max Events Print-Out
- Appendix B: Library
- Appendix C: SIA and Contact ID Event Codes
- Appendix D: SIA Event Structure
- Appendix E: Event Log Messages
|
Galaxy Programming Manual4446 - Group OmitOption 46 – Group Omit (Galaxy 18, 60, 128, 500 & 504)This option allows a level 6 user code to block omit all the omittable zones that are open at the end of theconfirm time in a group or multiple groups. All zones in the required groups that have the omit attribute ena-bled (refer to option 52.4 = PROGRAM ZONES.Omit) are omitted when this option is selected. Groupscan be omitted and reinstated without setting and unsetting the system.On selecting the Group Omit Option the groups assigned to the user code and keypad are displayed as wellas the omit status of each group (Y below the group indicates that it is omitted, N indicates that it is not omit-ted). To omit a group, press the required key. The letter beneath the group number changes from N to Y. Toreinstate the group press the key to toggle from Y to N.NOTE: The level 6 user must have group choice to enter Group Omit.NOTE: The zones in the selected groups are omitted from the system as soon as the group is selected.On returning to the banner (normal or engineer) the keypad displays the message ZONES OMITTED.Omitted zones remain omitted for one set period only or until they are manually reinstated to the system.Galaxy 18, 60, 128, 500 & 504Outputs programmed as Zone Omit (mode programmed as reflex) are activated as soon as the zone isomitted and remains active until the zone is reinstated. If the output mode is programmed as latch, then theZone Omit outputs activate when the system is set and remain active until the system is unset — reinstatingthe omitted zones.
PreviousNext |