Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Section 1: Quick Setup
- Section 2: System Operation
- Direct Access
- Exiting from Engineer Mode
- Multi User Access
- Section 3: Setting Options
- Unsetting the System
- Card Setting Options
- Setting Features
- Omitted Zones
- Abort Time
- Section 4: Menu Options 11-19
- Option 12 – Timed Set
- Option 17 – Instant Part
- Section 5: Display Options
- Option 22 – Display Log (Quick Menu Option 4)
- Option 23 – System (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 24 – Print (Quick Menu Option 5)
- Option 25 – Access Doors
- Section 6: Test Options
- Option 32 – Outputs
- Section 7: Modify Options
- Option 42 – Codes (Quick Menu Option 8)
- Default Codes
- Escaping from Engineer Mode
- Programming Codes
- Option 43 – Summer (Quick Menu Option 9)
- Option 45 – Timer Control (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 46 – Group Omit (Galaxy 18, 60, 128, 500 & 504)
- Option 47 – Remote Access
- Option 48 – Engineer Access (Galaxy 512 only)
- Option 49 – Datelock (Galaxy 512)
- Section 8: Engineer 1
- Option 52 – Program Zones
- System Alarms
- Option 53 – Program Outputs
- Attributes
- Output Functions
- Option 54 – Links (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 55 – Soak
- Option 56 – Communications
- Telecom Module
- RS232 Interface Module
- ISDN Module
- Ethernet Module
- Option 57 – System Print
- Option 58 – Keypad
- Option 59 – Quick Menu
- Section 9: Engineer 2
- Option 62 – Full Test (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 63 – Options (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 64 – Assemble Zone (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 65 – Timers (Galaxy 18, 60, 128, 500, 504 & 512)
- Option 66 – Pre-checks (Galaxy 60, 128, 500, 504 & 512)
- Option 67 – Remote Reset
- Option 68 – Menu Access (Galaxy 60, 128, 500, 504 & 512)
- Appendix A : Door Control - MAX (MX01)
- Mounting the MAX
- Configuring a MAX Reader into the System
- Configuring as On-Line MAX
- Removing a MAX Reader from the System
- Operating Instructions (On-Line Modes)
- Max Events Print-Out
- Appendix B: Library
- Appendix C: SIA and Contact ID Event Codes
- Appendix D: SIA Event Structure
- Appendix E: Event Log Messages
|
Galaxy Programming ManualA-6Operating Instructions (On-Line Modes)The MAX must be presented with a valid user card to allow access. Opening the door while LED 2 ison activates an alarm; the buzzer sounds and LED 1 flashes until the door is closed.Activating the egress switch allows the door to be opened without activating an alarm when no cardhas been presented to the MAX.Gaining Access1. Ensure that LED 2 is on and all other LEDs are off.2. Swipe the MAX with a standard user or nightlock access user card. LED 2 switches off and LED 1switches on for the programmed Open Timeout.3. Open the door while the LED 1 is on and access the area.4. Close the door; LED 1 switches off and LED 2 switches on. The door must be closed within theprogrammed Close Timeout; if the door remains open longer than this, an alarm is activated.Nightlock Access (Stand-Alone Only)Only cards programmed as nightlock access users can gain access when the MAX is nightlocked. Theoperation is identical to the standard user card.NOTE: Access cannot be gained using a standard user card.Card-Held FunctionThe MAX card can be assigned a single menu option (refer to option 42.2.8 = CODES.UserCodes.MAX Function). To activate the function assigned to the MAX card, hold the card in front ofthe reader for three seconds; all of the LEDs switch on. If a keypad has been assigned to the MAXfunction then it displays the details of this option. If no keypad is assigned, pressing a key on any ofthe keypads assigned to a common group to the user displays the card-held function.Card-Held System SettingIf the MAX card is assigned one of the setting options (option 12, 13, 14 & 16 – 19), the card-heldfunctions starts the setting procedure for the groups assigned to the card.NOTE: If Group Restriction is assigned, then only the groups that are common to both the MAXreader and the MAX user are set.If all of the groups that are assigned to the MAX are set (either by the card-held function or by anyother setting means) all of the LEDs switch off.To unset the system using the MAX, swipe the reader with a valid MAX card. The MAX reader beepsand LED 2 switches on. All of the groups assigned to the MAX are instantly unset.Operating Instructions