2. InstallationRC700 / RC90 Option Fieldbus I/O Rev.14 31Installing a BoardWARNING Make sure that the power is turned OFF before installing/removing any boards orconnecting/disconnecting any cables. Working with the power ON is extremelyhazardous and may result in electrical shock and/or malfunction of equipment.1. Configure the board address jumper (JP1) on DeviceNet master board manufacturedby molex.You can install one Fieldbus master board to the PC with the EPSON RC+ 7.0installed.The board number should be “1”.Refer to the following table for JP1 configuration.Short SocketBoard No. C0 C1 C21 0: Short 0: Short 0: Short2. Install the DeviceNet master board manufactured by molex to the PCI bus of the PCwith the EPSON RC+ 7.0 installed. Installation methods of the DeviceNet masterboard manufactured by molex to the PCI bus and how to open the cover differdepending on the type of PC. Refer to the manuals of each PC on how to install theboard to the PCI bus.3. Connect the DeviceNet master board manufactured by molex with the DeviceNetnetwork.4. Start up the PC.5. Open the [applicomIO Console] installation folder and start the “applicomIO Console”application.Following is specified for [applicomIO Console] installation folder as default.C:\Program Files(x86)\BradCommunications\applicomIO\4.16. The [applicomIOR console] dialog box appears. Add the DeviceNet master boardmanufactured by molex.Click . PreviousNext |