2. InstallationRC700 / RC90 Option Fieldbus I/O Rev.14 95Installing a BoardWARNING Make sure that the power is turned OFF before installing/removing any boards orconnecting/disconnecting any cables. Working with the power ON is extremelyhazardous and may result in electrical shock and/or malfunction of equipment.1. Configure the board address dip switch (JP1) on PROFIBUS-DP master boardmanufactured by molex.You can install one Fieldbus master board to the PC with EPSON RC+ 7.0 installed.The board number should be “1”.Refer to the following table for JP1 configuration.SwitchBoard No. C0 C1 C21 OFF OFF OFF2. Install the PROFIBUS-DP master board manufactured by molex to the PCI bus of thePC with EPSON RC+ 7.0 installed. Installation methods of the PROFIBUS-DPmaster board manufactured by molex to the PCI bus and how to open the cover differdepending on the type of PC. Refer to the manuals of each PC on how to install theboard to the PCI bus.3. Connect the PROFIBUS-DP master board manufactured by molex with thePROFIBUS-DP network.4. Start up the PC.5. Open the [applicomIO Console] installation folder and start the [applicomIO Console]application.Following is specified for [applicomIO Console] installation folder as default.C:\Program Files(x86)\BradCommunications\applicomIO\4.16. The [Add New Board] dialog box appears. Add the PROFIBUS-DP master boardmanufactured by molex.Click . PreviousNext |