PLANNINGGUIDE5.15Specifications subject to change without notice. Phone: (800) 793-0093www.dacor.comDistinctive RangeDR30DNote 2EF2 Cabinet/countertop depth is at discretion of customer butcabinet face MUST NOT protrude further than rear of frontpanel, see product dimensions.3 Consult local code for exact location requirements.1 Vertical to combustible surface from range grate level; ifinstalling an overhead vent hood, also check the hoodspecifications for minimum required clearances.Non-combustiblesurface alongback wallrecommended10” (25.4 cm) Min.to combustible sidewalls above the range(both sides)30” (76.2 cm)Min.137 7/8(96.2 cm)Max.13” (33.0 cm)Max.418” (45.7 cm)Min. 1, 4Suggestedlocation ofutilities 34 Not applicable for cabinets more than a horizontaldistance of 10” (25.4 cm) from the edge of the range.Cutout DimensionsE F36” (91.4 cm)*30” (76.2 cm)** 30 1/16” (916mm)* Recommended** Minimumgas and Electrical Service■ The shaded area shown below denotes the location of the gas inletand the electrical junction box/receptacle. This is the recommendedlocation. For replacement purposes, the location of the existingutilities may be utilized provided they do not interfere with the sidesor rear of the range. Check local building codes for permissible gasvalve locations.■ An external manual shut-off valve must be installed between the gasinlet and the range for the purpose of turning on or shutting off gas tothe appliance.The installation must allow for the following:■ Access to the gas shut-off valve when the unit is installed.■ Access to the remote circuit breaker panel/fuse box when the rangeis in place.■ The gas supply piping, gas shut-off valve and the electrical junctionbox or receptacle must be located so they do not interfere with therange when it is installed.■ The junction box and gas shut off valve must be located so thatthe range can be pulled out for service while the appliance remainsconnected.Cabinet Layout■ Carefully check the location where the range is to be installed. Forbest performance, the range should be placed away from drafts thatmay be caused by doors, windows and heating and air conditioningoutlets.■ To reduce the risk of personal injury and to reduce accumulatedsmoke in the room, Dacor strongly recommends installing a rangehood. A range hood should project horizontally a minimum of five (5)inches beyond the face of the cabinets.■ All maximum and minimum dimensions and clearances shown in thediagram below must be maintained for safe operation.■ The range may be installed flush to the rear wall. A non-combustiblerear wall is not mandatory, but Dacor highly recommends installinga non-combustible material from the countertop level up to the venthood or installation of a backguard.■ Any openings in the wall behind the appliance or in the floorunderneath it must be sealed.REqUIRED cAbINEt DImENsIoNsCabinet tolerances: -1/16”, (+1.6mm) -0Document # PG-006 Revised 10/01/11 Page 2/2