PLANNINGGUIDE5.14Specifications subject to change without notice. Phone: (800) 793-0093www.dacor.comRanges equipped for installation in Canada:■ Ranges equipped for use in Canada come pre-wired with a 4-wire,66 inch (168 cm) long, appliance cord and NEMA 14-50P plug.■ Do not modify the factory wiring. The plug is designed to plug directlyinto a NEMA 14-50R electrical receptacle installed by a licensedelectrician.All other models:The conduit or appliance cord installed needs to be long enough to allowthe range to be pulled out from the wall for service, while remainingconnected. See next page for further details.The wiring to the range must:◊ Include a strain relief.◊ Be terminated by tinned leads, closed loop terminals or open endedspade lugs with upturned ends.Where local code permits, a 3 or 4 wire appliance cord may be used. Itmust:◊ Be UL listed type SRD or SRDT.◊ Be equipped with a NEMA 14-50P 4-wire plugor, where local code permits, a NEMA 10-50P3-wire plug.Distinctive™ Dual Fuel RangeDR30DOptional Backguard and Island Trim Part NumbersDescription Part NumberIsland trim kit (no backguard) ADTK306 inch trim kit ADB30069 inch trim kit ADB3009Electrical SpecificationsCircuit Required Total Connected Load240 Vac, 60 Hz., 30 Amp.* 5.7 kW (23.8 Amp.)The ratings above are for reference only - refer to the range's product datalabel for exact specifications.NOTE: This range is NOT designed for self-rimming installation orinstallation with a raised vent.1 1/8” (2.9 cm)Rear of front panel/oven doorFront of knobsFront of open doorFront panel3” (7.6 cm)Backguard*6” (15.2 cm)Backguard**** OptionalStandard*37 7/8”(96.2 cm)to35 3/4”(90.8 cm)Width at front panel:29 7/8” (75.9 cm)Finished side panel9” (22.9 cm)Backguard**1 1/8” (2.9 mm) to cookingsurface (top of grates) fromtop of trim26 1/2” (67.3 cm)28 1/2” (72.4 cm)24 3/8” (61.9 cm)46 3/8” (117.8 cm)All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.wARNINg• Observe all governing codes and ordinances duringplanning and installation. Contact your local buildingdepartment for further information.• This appliance must be installed in accordance withthe accompanying installation instructions.Document # PG05-006 Revised 10/01/10 Page 1/2* Two 120 Vac hot (L1 and L2), one neutral, one groundThe regulator inlet accommodates a 3/4” gas line. The range ships with a1/2” to 3/4” adapter connected to the regulator.gas - Electrical Access DimensionsA B C D4 3/4”(12.1 cm)22 1/8”(56.2 cm)8 3/4”(22.2 cm)13 3/4”(34.9 cm)BGasinletAC7/8” (2.2 cm) dia. electricalconnection hole in bottom*DRange electrical access,cover removedGAs AND ELEctRIcAL DImENsIoNsPRoDUct DImENsIoNsgas Supply Pressure Requirements*gas Type Manifold Pressure Minimum gas SupplyPressureNatural gas 5” water column 6” water columnLP 10” water column 11” water column* Maximum input gas supply pressure for all models is 1/2 p.s.i.7/8" to 1 1/8" dia. access hole