All specifications subject to change without notice. Phone: (800) 793-0093www.dacor.comPLANNINGGUIDERear wall orcountertop edgecountertop opening29 1/4” (74.3 cm)raised vent opening27 1/2” (69.9 cm)30 1/16” (76.2 cm)cabinet openingbelow countertopbelow countertopCabinet faceNotch countertopto width of cabinets3/8” min. (1.0 cm)countertop overhang1” min. (2.6 cm)to any combustiblesabove counter both sides20 3/8”(51.8 cm)to23 3/8”(59.4 cm)20 3/8”(51.8 cm)2 5/8” (6.7 cm)25”(63.5 cm)max.Countertop frontRear wall orcountertop edgecountertop opening29 1/4” (74.3 cm)raised vent opening27 1/2” (69.9 cm)30 1/16” (76.2 cm)*cabinet openingbelow countertopbelow countertopCabinet faceNotch countertopto width of cabinets3/8” min. (1.0 cm)countertop overhang1” min. (2.6 cm)to any combustiblesabove counter both sides23 3/8”(59.4 cm)2 5/8” (6.7 cm)25”(63.5 cm)max.Countertop frontCabinet faceCountertopRange trim restingon countertopRR30NI[F]S range3/8” min. (1.0 cm)flat countertopoverhang27 9/16” (70.0 cm)ERV30[15]raised vent3/8” min. (1.0 cm) spacerequired behind ERV30[15]chassis to clear stiffenerATKR30SRtrim kitinstalledCabinet faceCountertopRange trim restingon countertopBack ofside panelrests againstcabinet faceRR30NI[F]S range3/8” min. (1.0 cm)flat countertopoverhangATKR30SRtrim kitinstalled27 9/16” (70.0 cm)3 inchside panelERV30[15]raised vent3/8” min. (1.0 cm) spacerequired behind ERV30[15]chassis to clear stiffenerCOMBINATION INSTALLATIONSRR30NI[F]S Range with ERV3015Raised VentDocument # PGCI-029 Revised 03/21/13 Page 1/1■ All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.■ Countertop height: 34 3/4” (88.3 cm) min., 36 7/8” (93.7 cm) max.Countertop thickness: 1 5/8” (4.1 cm) max.■ Trim kit PN ATKR30SR is required for proper installation of a raisedvent with this range.■ The self-rimming installation of the RR30NI[F]S range and ERV30[15]raised vent create a “built-in” look where the range trim overlapsthe countertop on both sides and the raised vent trim overlaps thecountertop in back.■ IMPORTANT: When installing the range in this configuration,ventilation must be provided to allow for cooling of the ranges internalcomponents. See diagram, left.TOPVIEwSIDEVIEwSIDEVIEwTOPVIEwDOwNDRAFT ERV30[15] wITh SLIDE-IN, SELF-RIMMING INSTALLATION, 3” SIDE PANELS REMOVEDDOwNDRAFT ERV30[15] wITh SLIDE-IN, SELF-RIMMING INSTALLATION, 3” SIDE PANELS INSTALLED■ Observe all vertical cabinet clearances on specified on the RR30NIPlanning Guide sheet..■ A self-rimming countertop configuration is required for raised ventinstallation. On installations with a raised vent, when sliding the rangeinto position, it will stop when the rear of the control panel or sidepanels contact the notches toward the front of the countertop.