COPYRIGHT © 1999 CANON INC. CANON ADF FOR iR600 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON) 5-57CHAPTER 5 TROUBLESHOOTING1 E402II . TROUBLESHOOTINGA. Troubleshooting MalfunctionsStep12ActionGo to step 3.Replace the belt motor(M2).ChecksSet the DIP switch (SW1) on the ADFcontroller PCB as follows:Press the push switch (SW2). Does thebelt motor (M2) rotate?(To stop, press the push switch (SW2)once again.)Disconnect the connector (J72) on the beltmotor driver PCB.Set the meter range to ◊ 1Ω, and connectthe meter probes as indicated. Is theresistance about 1.1Ω for each?Y e s /N oYESNOCauseBelt motor (M2)1-31-42-52-61(black)2(white)3(red)4(yellow)5(blue)6(orange)1(black)2(white)3(red)4(yellow)5(blue)6(orange)1(black)2(white)3(red)4(yellow)5(blue)6(orange)1(black)2(white)3(red)4(yellow)5(blue)6(orange)J72Motor driverPCB