7. System Setup7.10 Configuration Menu > Initial SetupGeneralIn this procedure, you will run the Event Master Toolset Software (EMTS), verify communication between theEvent Master seriesprocessor (EMP) and the program to the local network and perform basic setup.Prerequisite• Ensure that you are familiar with the Configuration Menu. For details on this menu, please refer to chapter "ConfigurationMenu", page 96Setup1. Connect the PC running the EMTS to the same local network switch that the EMP is connected to. Run the EMTS and thesoftware should connect to EMP automatically. The unit is listed in the System configuration page under the Discovered tabwith the button on turning yellow.2. Drag and drop the EMP from the device area into the middle diagram area.3. If multiple units are connected to the PC, the yellow LEDs next to the system will turn green. You can assign a unique name toeach unit. Confirm that you are connected to the right unit by clicking the arrow in front of EMP to reveal the unit’s IP address.Verify that this address is the same as the address listed on the unit’s front panel on the top status menu.Note: If the unit doesn’t connect automatically to the PC, you can type the PC’s IP address in the field under “Manual Connect”.A reason for this can be the PC´s firewall settings. Be sure to allow full communication for EMTS and EMP.4. (Optional) Select the EMP´s native vertical refresh rate from the “Native Rate:” drop-down menu. Default value is 59.94Hz.5. (Optional) Select the EMP´s Scaler capacity from the “Scaler Mode:” drop-down menu. Possible are 2K / DL and 4K setting themaximum scaling capacity for the Layer. Default value is 2K (HD).6. (Optional) Select the EMP´s Genlock mode from “Genlock” drop-down menu. Default value is OFF.R5905948 EVENT MASTER DEVICES 17/07/2017 229