Page 8 AB-G200L-REM-I01-150914COMMISSIONING THE STOVEOnce the fire is in place, connected, flued correctly, and the logs are in place, you canproceed with lighting the stove and ensuring the all the features are working correctly. The Fire control unit is located behind the right-hand foot of the stove. The pilot light is located at the front toward the left hand side of the burner. Should the stove be extinguished for any reason wait 3 minutes before attemptingre-ignition. Connect a suitable pressure gauge to the pressure test point to check the correctinlet pressures. Fit AA batteries to the Fire control unit. The control requires 3 AA size alkalinebatteries to be inserted under the battery compartment cover. The orientation ofthese is shown moulded into the battery compartment. After fitting the batteries and replacing the cover the fire can now be operated. Slide the Master switch to the right to the ON position (I symbol). To start the fire, press the ON/OFF button and hold for 1 second then release. Theburner will within around 1 to 10 seconds ignite and adjust to the maximum powersetting. . This can take longer on the first lighting as it has to clear out any airlocks, also if it is an LPG burner and has been stood unused for time, the gas couldhave settled in the pipework. The power of the burner can be adjusted up and down by pressing the + and -buttons. To stop the fire, simply press the power button again and the burner will stop.Once the fire has been successfully lit and extinguished, you can then put batteries inthe Remote control and check that this is functioning correctly (See user instructions forhow to set the time and date on the handset).CHECK FOR SPILLAGEClose all doors and windows in the room containing the appliance. Light the stove andset the control unit to ‘HIGH’, leave the appliance for 5 minutes.Apply a smoke match along the bottom edge of the draught diverter. The installation issatisfactory if the smoke is drawn into the stove. If in doubt wait a further 10 minutesand then repeat the test.If there is a nearby room with an extractor fan the spillage test should be repeated withthe fan running and all connecting doors between the stove and the fan left open.If in doubt disconnect the appliance and seek expert advice.