Page 5 AB-G200L-REM-I01-150914INSTALLATIONInstall the stove in accordance with the requirements given below. If a concealed gasconnection is to be made prepare the pipe work prior to installing the stove.Positioning the StoveClearances from non-combustible material in the fireplace opening must be at least50mm on the left side, 150mm on the right hand side and 75mm at the back. Thesedistances must be extended to a minimum clearance of 400mm from any combustiblematerial.HearthThe stove must stand on a fireproof hearth made of non-combustible material of aminimum thickness 12mm and be of sufficient size to accommodate the stove (seeFig.1).Fire Surround & ShelvesIt is recommended that a fire surround should not be closer than 400mm from thestove, if manufactured from a combustible material.A combustible shelf may be fitted provided that it is not more than 150mm deep andthere is at least 400mm clearance from the top of the stove.Log ArrangementThe logs should only be arranged as shown in the layout given in the InstallationInstructions by a qualified person.The stove must only be fitted with the ceramics supplied. DO NOT use any extra logs orcoals.Flue Connection The flue should be a minimum of 3m high and at least 125mm diameter orequivalent area. Horizontal or negative gradients in the flue pipe should be avoided. It is recommended that a minimum height of 610mm from the stove should beestablished before any significant change in the direction of the flue. An optional rear flue attachment is available as an accessory fromwww.acquisitions.co.uk (see Fig.1).