Page 2 AB-G200L-REM-I01-150914INSTALLATION INSTRUCTIONSCONTENTSImportant Notes Page 2 Commissioning the Stove Page 8Technical Information Page 3 Check for Spillage Page 8Dimensions and Clearances Page 4 Customer Briefing Page 9Installation Page 5IMPORTANT NOTES This stove is a fuel effect radiant convector. Before installation, ensure that thelocal distribution condition (identification of the type of gas and pressure) and theadjustment of the appliance are compatible. The data label is located at the rear ofthe stove. The installation must be in accordance with these Instructions andNational Regulations and must be carried out by a qualified installer. Any flue damper plate or flue restrictor must be removed or fixed permanently inthe fully open position, or shall only be fitted in accordance with NationalRegulations. If the chimney has previously been used to burn solid fuel, the chimney should beswept before the stove is installed. Before the stove is installed a flue test in accordance with National Regulationsshould be carried out. The gas connection must be in accordance with NationalRegulations. The stove is fitted with a spillage monitoring system consisting of a thermal switchconnected to a thermocouple interrupter. This system is not adjustable, and mustnot be put out of action. If any parts of the spillage monitoring system requirereplacement only original manufacturers’ parts must be used. All surfaces except the control unit are considered to be working surfaces. The stove should not be used for any other purpose than as a room heater and adecorative stove.