Location of Water and air unit, type Sb (SpotPack Basic)The Water and air unit type Sb is located as shown in the figure below. The figureshows the water and air unit fitted on IRB 6600, but the principle is the same forthe other models.xx0800000115Water and air unit, type SbAConnection boxBBracket, connection boxCBracket right (Bracket left on other side. Not shown here)DClamp holder with plastic clampEPROC 1 on robot basePROC 1PROC 2 on robot basePROC 2PROC 3 on robot basePROC 3PROC 4 on robot base (option)PROC 4Tightening torque, brass couplings 1/2": 31NmCAUTIONDo not tighten the brass couplings for waterand air with excessive force.Tightening torque, brass couplings 3/8": 17NmGeneral technical dataThe table below shows technical data of the water and air pressure:ValueParameterMax. 0.6 MPa / 87 PSIWater operating pressureMax. 1.0 MPa / 145 PSIAir operating pressureThe table below shows technical data for water and air quality:ValueParameterNormal filtered industrial water quality, 80 to100 mesh.Water qualityContinues on next page176 Product manual - DressPack/SpotPack IRB 66403HAC028638-001 Revision: K© Copyright 2007-2018 ABB. All rights reserved.2 Installation2.6.1 Installation of Water and air unitContinued