42 Document MT0605P.2018.E© Xsens Technologies B.V. MTi User Manual7.4.2 Dimensions MTiThe MTi 10-series and the MTi 100-series (including MTi-G-710) have an identical footprint and (positionof the) connector. Differences in casings are limited to colour, barometer holes (MTi 100-series only)and SMA connector (MTi-G-710 only).7.4.3 Mounting the MTi-OEMThe MTi-OEM has four mounting holes (holes for M1.6 screws). In order to lower and tighten the screws,it is convenient to use a piece of heat shrink tube placed over the holes.Figure 14: Using a heat shrink tube to position the mounting screwsMake sure when mounting the MTi to maintain a clearance of at least 3.4 mm +/- 0.1 mm from thesurface of the PCB.