About Truecharge™ 2 Battery Charger975-0401-01-01 2–5Charging Voltage SetpointsThe Truecharge™ 2 Battery Charger charging process isdesigned to make the battery or battery banks reach thefollowing voltage setpoints.Battery QualificationThe Truecharge™ 2 Battery Charger will perform a batteryqualification on each application of AC (or DC > 9 V), todetermine if battery banks are present and healthy.To force a battery detection sequence,1. Turn off AC.2. Wait approximately 20 seconds or until all lights on thecharger or remote have gone out.3. Turn on AC.The charger will then perform a battery detection whenAC is reappliedTable 2-1 Charging Maximum Voltages for 12 Vdc chargersBattery TypeAbsorption(Volts) Float (Volts)Equalization(Volts)Flooded 14.4 13.5 16.0GEL 14.2 13.8 not applicableAGM 14.3 13.4 not applicableLead-Calcium 15.5 13.5 16.0Table 2-2 Charging Maximum Voltages for 24 Vdc chargersBattery TypeAbsorption(Volts) Float (Volts)Equalization(Volts)Flooded 28.8 27.0 32.0GEL 28.4 27.6 not applicableAGM 28.6 26.8 not applicableLead-Calcium 31.0 27.0 32.0