5-4ELECTRICAL SHOCK HAZARDDisconnect power before servicing.Replace all panels before operating.Failure to do so could result in death orelectrical shock.WARNINGOVEN SHUTDOWN THERMAL FUSERefer to page 4-16 for the procedure for servic-ing the oven shutdown thermal fuse.1. Disconnect the electrical power to theoven.2. Disconnect the wires from the oven shut-down thermal fuse terminals.3. Set the ohmmeter to the R x 1 scale.4. Touch the ohmmeter leads to the ovenshutdown thermal fuse terminals. Themeter should indicate continuity (closedcircuit).ELECTRICAL SHOCK HAZARDDisconnect power before servicing.Replace all panels before operating.Failure to do so could result in death orelectrical shock.WARNINGRefer to page 4-7 for the procedure for servic-ing the oven door latch assembly.1. Disconnect the electrical power to theoven.2. Disconnect the wires from the door latchassembly component under test.3. Set the ohmmeter to the R x 1 scale.4. To test the solenoid, touch the ohmme-ter leads to the terminals. The meter shouldindicate between 47 and 54 Ω.5. To test the door or latch switch:a) Touch the ohmmeter leads to the fol-lowing terminals (shown embossed onthe switch). The meter should indicate:COM to N.O. = infinity (no continuity)COM to N.C. = 0 Ω (continuity)b) Press the switch actuator button andtouch the ohmmeter leads to the fol-lowing terminals. The meter should in-dicate:COM to N.O. = 0 Ω (continuity)COM to N.C. = infinity (no continuity)DoorSwitchLatchSwitchSolenoidOVEN DOOR LATCH ASSEMBLY