VARI❋LITE® - VL2000™ WASH LUMINAIRE U SER ’S M ANUAL54 17-Sep-02 02. 9671. 0001 EError MessagesIf a problem occurs during luminaire calibration, at the end of the calibration sequencethe Menu Display will cycle through any applicable error message(s), one at a timeuntil the end of the list is reached. To review the error messages again, it will benecessary to access them using the Status function. (Refer to “Troubleshooting” onpage 84 for a list of possible causes and remedies associated with the error messages.)To access error messages:Step 1. Press [Menu].Step 2. Press [Up] / [Down] arrows until Fixt (Fixture) appears. Press [Enter].Step 3. Press [Up]/ [Down] arrows to access STAT. Press [Enter]. (Display willnow scroll through any error messages or display OK if no errors.)Table 4-1: Error MessagesDisplay Message...OK No Errors FoundB1M1 / MAG / NoSn Aux Board 1, Motor 1 / Magenta / Sensor Not FoundB1M1 / MAG / SAct Aux Board 1, Motor 1 / Magenta / Sensor Always ActiveB1M2 / Dimm /NoSnAux Board 1, Motor 2 / Dimmer / Sensor Not FoundB1M2 / Dimm / SAct Aux Board 1, Motor 2 / Dimmer / Sensor Always ActiveB1M3 / CWhl / NoSn Aux Board 1, Motor 3 / Color Wheel / Sensor Not FoundB1M3 / CWhl / SAct Aux Board 1, Motor 3 / Color Wheel / Sensor Always ActiveB2M1 / Blue / NoSn Aux Board 2, Motor 1 / Blue / Sensor Not FoundB2M1 / Blue / SAct Aux Board 2, Motor 1 / Blue / Sensor Always ActiveB2M2 / Ambr / NoSn Aux Board 2, Motor 2 / Amber / Sensor Not FoundB2M2 / Ambr / SAct Aux Board 2, Motor 2 / Amber / Sensor Always ActiveBRD1 / NO / COMM Aux Board 1 Communication FailureBRD2 / NO / COMM Aux Board 2 Communication FailureHEAD/ OVER/TEMPHead Over TemperatureLAMP / STRK / FAIL Lamp Strike FailurePAN / ENCR / FAIL Pan Encoder FailurePAN / NO / SENS Pan Sensor Not FoundPAN / SENS / ACTV Pan Sensor Always ActiveSRCH/FOR/BRD1 Attempting to communicate with Board 1SRCH/FOR/BRD2 Attempting to communicate with Board 2TILT / ENCR / FAIL Tilt Encoder FailureTILT / NO / SENS Tilt Sensor Not FoundTILT / SENS / ACTV Tilt Sensor Always Active