V2 CITY1 Manual
Also see for CITY1: Manual
ENGLISH26IMPORTANT REMARKSFor any installation problem please contact our Customer Serviceat the number +39-0172.812411 operating Monday to Fridayfrom 8:30 to 12:30 and from 14:00 to 18:00.V2 has the right to modify the product without previousnotice; it also declines any responsibility to damage orinjury to people or things caused by improper use orwrong installation. Please read this instruction manual very carefullybefore installing and programming your control unit.• This instruction manual is only for qualified technicians,who specialize in installations and automations.• The contents of this instruction manual do not concern theend user.• Every programming and/or every maintenance serviceshould be done only by qualified technicians.AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCEWITH THE EUROPEAN REGULATIONS IN FORCE:EN 60204-1 (Machinery safety. electrical equipment ofmachines, part 1: general rules)EN 12445 (Safe use of automated locking devices,test methods)EN 12453 (Safe use of automated locking devices,requirements)• The installer must provide for a device (es. magnetotermicalswitch) ensuring the omnipolar sectioning of the equipmentfrom the power supply.The standards require a separation of the contactsof at least 3 mm in each pole (EN 60335-1).• After making connections on the terminal board, use onehose clamp to fix dangerous voltage wires near the terminalboard and another hose clamp to fix safety low voltage wiresused for accessories connection; this way, in case ofaccidental detachment of a conducting wire, dangerousvoltage parts will not come into contact with safety lowvoltage ones.• The plastic case has an IP55 insulation; to connect flexibleor rigid pipes, use pipefittings having the same insulationlevel.• Installation requires mechanical and electrical skills,therefore it shall be carried out by qualified personnel only,who can issue the Compliance Certificate concerning thewhole installation (EEC Machine Directive 89/392, Annex IIA).• The automated vehicular gates shall comply with thefollowing rules: EN 12453, EN 12445, EN 12978 as wellas any local rule in force.• Also the automation upstream electric system shall complywith the laws and rules in force and be carried outworkmanlike.• The door thrust force adjustment shall be measuredby means of a proper tool and adjusted according tothe max. limits, which EN 12453 allows.• We recommend to make use of an emergencybutton, to be installed by the automation (connectedto the control unit STOP input) so that the gate maybe immediately stopped in case of danger.• Always remember to connect the earth according tocurrent standards (EN 60335-1, EN 60204-1).DECLARATION OF CONFORMITYV2 S.p.A. hereby declare that CITY1 products conform to theessential requirements established in the following directives:- 89/336/CEE (EMC Directive in accordance with standardsEN 55014-1, EN 55014-2, EN 61000-3-2, 61000-3-3)- 2006/95/CEE (Low Voltage Directive in accordance withstandards EN 60335-1 + EN 60335-2-103)- 99/05/CEE (Radio Directive in accordance with standardEN 301 489-3)Racconigi, 12/01/2009V2 S.p.A. legal representative.Antonio CristinaTECHNICAL SPECIFICATIONSDESCRIPTION OF THE CONTROL UNITThe digital control unit CITY1 is an innovative V2 product thatguarantees a safe and reliable automation of leaf swing orsliding gates.CITY1 is provided with a display that, not only makesprogramming simple, but also allows a continuous monitoring ofthe input statuses; in addition, thanks to a menu structure, theworking schedule and the operation logic can be set easily.In compliance with the European standards concerningelectrical safety and electromagnetic compatibility(EN 60335-1, EN 50081-1 and EN 50082-1) it has beenequipped with the low voltage circuit total electric insulation(motors included) from the network voltage.Other characteristics:• Automatic control for the null current relay switch.• Power adjustment with independent wave shuttingon both the two motors.• Obstacle detection by means of monitoring startcondenser voltage.• Automatic learning of the operation time.• Operation by means of mechanical ends of strokeconnected to the gearcase or connected in series tothe motor.• Tests for safety devices (photocells, safety ribbons andtriacs) before each opening.• Deactivation of safety inputs through the configurationmenu: no jumper is required for terminals concerning safetydevices that have not been installed, yet. You will only needto disable this function from its relevant menu.• Control unit programming can be locked through the optionalCL1 key.• Also available in the CITY1-ECD model (p/n 12G033), whichallows you to control ENCODER-equipped 230V motors.CITY1 CITY1-120VPower supply 230VAC - 50Hz 120VAC - 60HzMax motors load 2 x 700W 2 x 500WDuty clcle 40% 30%Max accessories load 24V 10W 10WWorking temperature -20 ÷ +60°C -20 ÷ +60°CProtection fuse F1 = 5A F1 = 8ADimensions 295 x 230 x 100 mmWeight 1600gProtection IP55 |
Related manuals for V2 CITY1
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved