* Scan “B7” to end* Scan “Exit” to exit setupThere is only total 24 characters space available for defining these three labels. Ifone of the labels has been defined for the output with 24 characters, the other twolabels cannot be defined further.Quick SetupAppendix A has a quick setup chart, which gives you one-label-for-one-functionconvenience to set up the scanner. To set up the scanner, locate the label with thefunction you want and scan that label.Batch SetupIf you need to configure more than one scanner, you may duplicate the settings ofthe scanner (master) to the others. You can do this by producing a set of customsetup labels derived from the master scanner, and by scanning these labelsconfiguring the other scanners.The following label is called “Dump Settings” label. Before you scan the label,please open a text editor application (such as Notepad, Word, etc.). Scan thefollowing label and the settings of the scanner will dump to the screen as one orseveral ASCII string(s). Use a barcode printing software, select Code 39 symbology,and use the string(s) to generate barcode labels. You use this batch setup labels toduplicate setting to the other scanners.Dump SettingsIf you have settings as follows:* Device Type is “Keybaordless Wedge”.* Do not send the check digit of UPC-A and EAN-13.* Define Preamble as “”.* Define Postamble as “”.* Define Label 0 as “START”.When dumping settings on a PC/AT, you have the following strings:...I800C06D51DJ808080A0O7C005354415254.Print into Code 39 bar code labels:. . . I 8 0 0 C0 6 D5 1 DJ 80 8 0 8 0 A0 O7 C0 0 5 3 5 4415254.24