STORAGE, VACATION AND MOVINGIf the unit is to be stored, moved or not used for extended periods, itwill be necessary to drain the system of water.Electrical Shock Hazard. Disconnect powerbefore servicing. Before operating replace allpanels. Failure to do so can result in death orelectrical shock.1. Disconnect power from theunit.2. Remove ice from the stor-age bin.3. Shut off water supply at themain water source.4. Remove grille (2 screws).5. Remove the front accesspanel (2 screws) (seeFigure 4).6. Disconnect the inlet andoutlet lines to the watervalve and allow them todrain (see Figure 29).If the ambient temperature is expected to drop below 40°F,drain all water from the unit to prevent freezing damage notcovered by the warranty.NOTEThe use of anti-freeze or other products of this nature is notnecessary and is not recommended.! WARNING! WARNING27UL404WATERINLETWATEROUTLETICEOFFCLNFigure 29