NOTEAfter completing the installation, turn on the water andrecheck water and drain connection for leaks. Apply addi-tional tightening if needed. Do NOT use thread sealing com-pound or tape.NOTERoute the water supply line through the clip on the sidewallof the unit in such a way as to prevent the line from com-ing in contact with any internal components other than thesolenoid valve (see Figure 5). Normal operation createssome vibration. A water supply line contacting an internalcomponent or cabinet wall may cause excessive noise dur-ing operation or damage to the line.7. Re-install back panel and grommet.8. Install access panel.9. Install the grille. See CONDENSER CLEANING.10. Plug in the power cord.11. Gently push the unit into position. If desired the unit may berecessed into cabinet or wall.12. Allow at least 1-1/2 inches clearance behind the unit for electri-cal, water supply and drain connections.LEVELING THE UNITNOTEIt is extremely important that the unit is level. If it is notlevel, the ice mold will not fill evenly. This can cause a reduc-tion in ice rate, uneven sized cubes or water spilling into thestorage area which will cause the ice in the bin to melt pre-maturely. Remember that floors near drains have a ten-dency to slope towards the drain.1. Use a level to check the levelness of the ice maker from front toback and from side to side (see Figure 10).2. If the ice maker is not level, adjust the feet on the corners of theunit as necessary (see Figure 11).13