9. SpecificationsThe flowmeter specifications and the type specification code used when ordering the flowmeterare described in this chapter.9.1 SpecificationsMeter size: 15, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600mmMeasuring range: 0-0.3m/s to 0-10m/s (measuring range by flow rate conversion)(0-0.1m/s to 0-0.3m/s range is available optionally for meter sizes 15mm to 450mm.)Accuracy: (Accuracy when combined with the converter)< 1/2” to 18”( 15mm to 450 mm ) >±0.2 % of Rate ** This pulse output error result is established under standard operating conditions at Toshiba'sadmitted flow calibration facility.* Individual meter’s measurement error may vary up to ±0.5% of Rate at 1.64 ft/s (0.5m/s) or moreand ±0.3% of rate ±0.039 inch/s (1mm/s) at 1.64 ft/s or less.* Current output: plus ± 8μA (0.05% of span).* Refer to individual calibration data for each individual meter's measurement error.< 20” to 24” ( 500mm to 600mm ) >± 0.3 % of Rate ** This pulse output error result is established under standard operating conditions at Toshiba’sadmitted flow calibration facility.* Individual meter’s measurement error may vary up to ±0.5 % of Rate at 3.28 ft/s (1.0 m/s) or moreand ± 0.3% of Rate ±0.079 inch/s (2 mm/s) at 3.28 ft/s (1.0 m/s) or less.* Current output: plus ± 8μA (0.05% of span.)* Refer to individual calibration data for each individual meter’s measurement error.