E6581422③1. OverviewThis option allows the VF-S11 inverter to be connected into a CC-Link network. CC-Linksupports a maximum of 42 nodes, allowing for the Master unit and this option is based onCC-Link Ver.1.10.The CCL002Z is able to operate RUN/STOP, monitor the status of the inverter, set theinverter's parameter and etc. by the CC-Link master through installing the VF-S11. And itcan use different applications.2. Name of functions of main parts2.1. Exterior featuresHere are the name and functions of the exterior components of the CCL002Z unit.CC-Link connectorPhoenix Contact corp.MC 1,5/5-ST-3,81Input terminalSINK/SOURCE select SWV/I functions of VIA select SWOptional RJ45 communication portTermination resistorsselect SWLeft : 110 ohmCenter : noneRight : 130 ohmDADBDGSLDFGCN2 TB1SW4SW2-underSW2-upperDo not touch this switch.It uses for only maintenance.SW1 and SW3RJ45 communication option can beused. However it makes CC-Linkcommunication be disabled.Status LEDCC-Link communicationL.RUN Light on during communication.SD Light on during send the data of CC-Link.Light on during received the data ofCC-Link.RDL.ERR Light on during communication error- 6 -