0Command ListVISCA Device Setting CommandBefore starting control of the FCB camera, be sure tosend the Address command and the IF_Clearcommand using the broadcast function.For VISCA network administration AddressSets an address of a peripheral device. Use wheninitializing the network, and receiving the followingnetwork change message. Network ChangeSent from the peripheral device to the controllerwhen a device is removed from or added to thenetwork. The address must be re-set when thismessage is received.Packet NoteAddress 88 30 01 FF Always broadcasted.Network Change X0 38 FFX = 9 to F: FCB camera address + 8VISCA interface command IF_ClearClears the command buffers in the FCB camera andcancels the command currently being executed.Command Packet Reply Packet NoteIF_Clear 8X 01 00 01 FF X0 50 FFIF_Clear (broadcast) 88 01 00 01 FF 88 01 00 01 FFX = 1 to 7: FCB camera address (For inquiry packet)X = 9 to F: FCB camera address +8 (For reply packet)VISCA interface and inquiry CAM_VersionInqReturns information on the VISCA interface.Inquiry Inquiry Packet Reply Packet DescriptionCAM_VersionInq 8X 09 00 02 FF Y0 50 GG GG HH HH JJ JJ KK FF GGGG = Vender ID(0020: Sony)HHHH = Model ID0467: FCB-EV7500JJJJ = ROM revisionKK = Maximum socket #(02)X = 1 to 7: FCB camera address (For inquiry packet)X = 9 to F: FCB camera address +8 (For reply packet)