Command ListVISCA Camera-Issued MessagesAcknowledge/Completion MessagesCommand Command Message CommentsAcknowledge z0 4y FF(y: Socket No.)Returned when the command is accepted.Completion z0 5y FF(y: Socket No.)Returned when the command has been executed.z = Address of device that issued the message + 8 (Locked to “z = 9” for VISCA over IP.)Error MessagesCommand Command Message CommentsSyntax Error z0 60 02 FF Returned when the format is different or when a command with illegalparameters is accepted.Command Buffer Full z0 60 03 FF Could not accept a command that is received while two commands arecurrently being executed (two sockets have been used).Command Canceled z0 6y 04 FF(y: Socket No.)Returned when a command which is being executed in a socketspecified by the cancel command is canceled. The completion messagefor the command is not returned.No Socket z0 6y 05 FF(y: Socket No.)Returned when no command is executed in a socket specified by thecancel command, or when an invalid socket number is specified.Command Not Executable z0 6y 41 FF(y: Socket No.)Returned when a command cannot be executed due to currentconditions. For example, when a command for controlling the manualfocus is received during the auto focus mode.z = Address of device that issued the error + 8 (Locked to “z = 9” for VISCA over IP.)Network Change Message*Command Command Message CommentsNetwork Change z0 38 FF Issued when power is supplied to the camera.* Not available for VISCA over IP.