Scale parameters and functions8.21 DR 32 display of data and operator errorsSIWAREX WP231Manual, 07/2014, A5E31238908A-02 121Variable Note Type Length(bytes)Rw Default Min. Max. Modbusregisters6002 Recording not possible because weightiinvalidBIT r 0 0 1 3505.57000 Permitted number range violated BIT r 0 0 1 3506.16BIT r 0 0 1 3506.157001 Regulation code unknown BIT r 0 0 1 3506.147002 Specifications of string lengths not plausi-bleBIT r 0 0 1 3506.137003 Specification of date / time not plausible BIT r 0 0 1 3506.127004 Assignment of digital inputs/outputs incor-rectBIT r 0 0 1 3506.117006 Command only possible in test field BIT r 0 0 1 3506.107007 The calibration weights or calibrationdigits are not plausibleBIT r 0 0 1 3506.97008 Zeroing/zero setting or tare parameter notplausibleBIT r 0 0 1 3506.87009 Standstill range / standstill wait time notplausibleBIT r 0 0 1 3506.77010 Scale interval / rounding not plausible BIT r 0 0 1 3506.67011 Filter parameter not plausible BIT r 0 0 1 3506.57013 Interface assignment for verifiable HMInot plausibleBIT r 0 0 1 3506.4Reserve - BIT r 0 0 1 3506.3Reserve - BIT r 0 0 1 3506.27016 Parameter assignment of analog outputnot plausibleBIT r 0 0 1 3506.17017 MAC address cannot be changed BIT r 0 0 1 3607.167018 Error in IP mask BIT r 0 0 1 3607.157019 RS485 parameter error BIT r 0 0 1 3607.14Reserve - USHORT 2 r 0 - - 3504Reserve - USHORT 2 r 0 - - 3505Reserve - USHORT 2 r 0 - - 3506Reserve - USHORT 2 r 0 - - 3507Reserve - USHORT 2 r 0 - - 3508Modbus RTUerror code(Page 123)Synchronous error code for communica-tion at the Modbus RS485 interfaceUSHORT 2 r 0 - - 3509ModbusEthernet errorcode(Page 123)Synchronous error code for communica-tion at the Modbus Ethernet interfaceUSHORT 2 r 0 - - 3510SIWATOOLerror code(Page 123)Synchronous error code for communica-tion at the SIWATOOL interfaceUSHORT 2 r 0 - - 3511Error codefollowingcommands atdigital input(Page 123)Synchronous error code caused by com-mand at the DIUSHORT 2 r 0 - - 3512Reserve - USHORT 2 r 0 - - 3513