08/2005 Overview of Alarms2-439© Siemens AG, 2005. All rights reservedSINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 EditionRemedy: Program tool (T).Program Con-tinuation:Clear alarm with the RESET key. Restart part program61010 Channel %1 Block %2: Finishing allowance too largeParameters: %1 = Channel number%2 = Block number, labelDefinitions: The finishing allowance for the base is greater than the total depth. Alarm triggered by fol-lowing cycle: CYCLE72.Reactions: - Alarm display.- Interface signals are set.- NC Start disable in this channel.- Interpreter stopRemedy: Reduce finishing allowance.Program Con-tinuation:Clear alarm with the RESET key. Restart part program61011 Channel %1 Block %2: Scaling not permissibleParameters: %1 = Channel number%2 = Block number, labelDefinitions: A scale factor is active which is illegal for this cycle. Alarm triggered by following cycles:CYCLE71, CYCLE72.Reactions: - Alarm display.- Interface signals are set.- NC Start disable in this channel.- Interpreter stopRemedy: Modify scale factor.Program Con-tinuation:Clear alarm with the RESET key. Restart part program61012 Channel %1 Block %2: Different scaling in planesParameters: %1 = Channel number%2 = Block number, labelDefinitions: Alarm triggered by following cycles: CYCLE76, CYCLE77.Reactions: - Alarm display.- Interface signals are set.- NC Start disable in this channel.- Interpreter stopRemedy: --Program Con-tinuation:Clear alarm with the RESET key. Restart part program61013 Channel %1 Block %2: Basic settings were changed, program cannot be executedParameters: %1 = Channel number%2 = Block number, label channel numberDefinitions: The basic settings are not compatible with the generated program. Alarm triggered by fol-lowing cycles: E_CP_CE, E_CP_CO, E_CP_DR, F_CP_CE, F_CP_CO, F_CP_DR.Reactions: - Interpreter stop- NC Start disable in this channel.- Interface signals are set.- Alarm display.