Manual and Handwheel Travel (H1)4.9 Start-up: HandwheelsExtended FunctionsFunction Manual, 01/2008, 6FC5397-1BP10-3BA0 3134.9.2 Connection via cable distributorParameter settingParameterization of handwheels connected via cable distributor is done via the followingNCK machine data:● MD11350 $MN_HANDWHEEL_SEGMENT[<Handwheel_No._in_NCK - 1 >] = 1When connected via cable distributor, the hardware segment has always to be enteredas 1 (local hardware segment).● MD11351 $MN_HANDWHEEL_MODULE[<Handwheel_No._in_NCK - 1 >] = 1When connected via cable distributor, the hardware module has always to be enteredas 1.● MD11352 $MN_HANDWHEEL_INPUT[<Handwheel_No_in_NCK - 1 >] = <Handwheelconnection >Handwheel connection used: 1 or 2NoteA maximum of two handwheels can be connected via the cable distributor.ExampleDirect connection of 2 handwheels via a cable distributor.Parameter setting:Machine data Value Description1st handwheel:MD11350 $MN_HANDWHEEL_SEGMENT[0] 1 Connection via cable distributor always 1MD11351 $MN_HANDWHEEL_MODULE[0] 1 Connection via cable distributor always 1MD11352 $MN_HANDWHEEL_INPUT[0] 1 1st handwheel connection at cable distributor2nd handwheel:MD11350 $MN_HANDWHEEL_SEGMENT[1] 1 Connection via cable distributor always 1MD11351 $MN_HANDWHEEL_MODULE[1] 1 Connection via cable distributor always 1MD11352 $MN_HANDWHEEL_INPUT[1] 2 2nd handwheel connection at cable distributorReferences● SINUMERIK 840D/PHD/ NCU Configuration ManualChapter: Cable distributor (distributor box)● SINUMERIK 840Di/HBI/ Manual, SINUMERIK 840DiChapter: Hardware Descriptions >Cable distributor