SCALANCE network components4.9 Network management softwareIndustrial Ethernet274 System Manual, 09/2019, C79000-G8976-C242-10● Microsoft Windows Server 2008 R2 64-bit + Service Pack 1 (requirement: NET 3.5 orhigher is installed)● Microsoft Windows Server 2016 Standard (Desktop representation)● Microsoft Windows 10 Professional 64-bit● Microsoft Windows Server 2012 R2 64-bitLicensesWithout a license extension, you can configure four nodes with the SINEMA RC Server. Inaddition, a license for SINEMA Remote Connect is included. You can increase the number ofnodes with the following licenses:● SINEMA Remote Connect 64: This license supports up to +64 nodes.● SINEMA Remote Connect 256: This license supports up to +256 nodes.● SINEMA Remote Connect 1024: This license supports up to +1024 nodes.4.9 Network management software4.9.1 Primary Setup ToolDescriptionWith the Primary Setup Tool (PST), an address assignment (for example an IP address) ismade via the network for unconfigured SIMATIC NET network components, Ethernet CPsand gateways. This is only possible if the SIMATIC NET devices have a default ETHERNET(MAC) address and can be reached online in the network. The nodes must also support theDCP protocol. The PST uses a filter view to allow a clear presentation of modules anddevices.NoteThe Primary Setup Tool supports only SIMATIC NET Ethernet network components withmanagement functionality (Web-based Management and/or SNMP). With thesecomponents, you also have the option of calling Web-based Management for diagnosticsand configuration.