Issue 01/06 Parameter DescriptionMICROMASTER 440 Parameter List6SE6400-5BB00-0BP0 229P2227[3] Fixed PID setpoint mode - Bit 5 Min: 1CStat: CT Datatype: U16 Unit: - Def: 1P-Group: TECH Active: first confirm QuickComm.: No Max: 2Direct selection / direct selection + ON Bit 5 for PID setpoint.Possible Settings:1 Direct selection2 Direct selection + ON commandIndex:P2227[0] : 1st. Command data set (CDS)P2227[1] : 2nd. Command data set (CDS)P2227[2] : 3rd. Command data set (CDS)P2228[3] BI: Fixed PID setp. select Bit 5 Min: 0:0CStat: CT Datatype: U32 Unit: - Def: 722:5P-Group: COMMANDS Active: first confirm QuickComm.: No Max: 4000:0Defines command source of fixed PID setpoint selection Bit 5Index:P2228[0] : 1st. Command data set (CDS)P2228[1] : 2nd. Command data set (CDS)P2228[2] : 3rd. Command data set (CDS)Common Settings:722.0 = Digital input 1 (requires P0701 to be set to 99, BICO)722.1 = Digital input 2 (requires P0702 to be set to 99, BICO)722.2 = Digital input 3 (requires P0703 to be set to 99, BICO)722.3 = Digital input 4 (requires P0704 to be set to 99, BICO)722.4 = Digital input 5 (requires P0705 to be set to 99, BICO)722.5 = Digital input 6 (requires P0706 to be set to 99, BICO)P2231[3] Setpoint memory of PID-MOP Min: 0CStat: CUT Datatype: U16 Unit: - Def: 0P-Group: TECH Active: Immediately QuickComm.: No Max: 1Setpoint memoryPossible Settings:0 PID-MOP setpoint will not be stored1 PID-MOP setpoint will be stored (P2240 is updated)Index:P2231[0] : 1st. Drive data set (DDS)P2231[1] : 2nd. Drive data set (DDS)P2231[2] : 3rd. Drive data set (DDS)Dependency:If 0 selected, setpoint returns to value set in P2240 (setpoint of PID-MOP) after an OFF command.If 1 is selected, active setpoint is "remembered" and P2240 updated with current value.Details:See P2240 (setpoint of PID-MOP)P2232 Inhibit neg. PID-MOP setpoints Min: 0CStat: CT Datatype: U16 Unit: - Def: 1P-Group: TECH Active: first confirm QuickComm.: No Max: 1This parameter suppresses negative setpoints of the PID-MOP output r2250.Possible Settings:0 Neg. PID-MOP setpoint is allowed1 Neg. PID-MOP setpoint inhibitedNote:Setting 0 enables a change of motor direction using the motor potentiometer setpoint (increase/decreasefrequency either by using digital inputs or motor potentiometer up/down buttons.Level3Level3Level2Level2www . ElectricalPartManuals . com