AL-2020/2035/2040/2050/2060 FAX SOFT SWITCH 12 - 13SW561 CI signal ON detectionenable timeBinary input155ms02 Bit No.Set range1 2 30 (155ms) to 7 (225ms)Step 10ms03 04 Inhibited to use 05 DT/BT detectionfrequency rangeBit No. 5 6245Hz–650Hz1Modem fixed (400Hz) 0 0420Hz–680Hz 0 16 360Hz–440Hz 1 0 1245Hz–650Hz 1 17 Inhibited to use 08 1SW571 Inhibited to use 02 Sharp machine mode 1: ON 0: OFF ON 13 Inhibited to use 04 Reception gainadjustmentBinary input0.0dBm05 Bit No.Set range4 5 6 7 80 (+6.0dBm) to24 (–6.0dBm)Step 0.5dBm16 17 08 0SW581 Dual wait inhibit time afterCFR sendBinary input1600ms12 Bit No.Set range1 2 3 40 to 3000ms200ms unit03 04 05 FSK signal settlementtime in double waitBinary input550ms06 Bit No.Set range5 6 7 8Settlement time =50 (ms) x N + 200 (ms)17 18 1SW591 Inhibited to use 02 03 Reception SED ON level Bit No. 3 4–48dB1–43dB 0 0–38dB 0 14 –33dB 1 0 1–48dB 1 15 Transmission cableamplitude equalizerBit No. 5 60dB00dB 0 04dB 0 16 8dB 1 0 012dB 1 17 Reception cable amplitudeequalizerBit No. 7 80dB00dB 0 04dB 0 18 8dB 1 0 012dB 1 1SW601 Scan effective image areasub scan lead edge imageloss (RSPF back surface)Binary input96 lines02 Bit No.Set range1 2 3 40 to 240 lines16 lines interval13 14 05 Scan effective image areasub scan rear edge imageloss (RSPF back surface)Binary input144 lines16 Bit No.Set range5 6 7 80 to 240 lines16 lines interval07 08 1SW611 Inhibited to use 02 03 04 05 06 07 18 0SWNO.DataNo. Item Switch selection and contents of functions Initial value Remark