Inspection of the Controller7-177.3.4. Feeder Control BoardReceives commands from the CAN Master Board to operate the feeder solenoid valve. Required power supplyExternal power input: +24V DCInternal power required: +5V DC / +24V DC Description of major functions INPUTPIN NO. DEF. DESCRIPTION REMARK1 CANH CAN communication signal2 CANLConnection with CANcommunication signal of othernodesCN2/CN33 /IO-RES RESET Signal FROM CAN MASTER1 24VP DC+24V for OUTPUT PORT Apply after inputting the READYSW2 24V DC+24V for INPUT PORT then DC+5V for BOARD isgeneratedCN43/4 24G DC+24V GROUND -CN9 1~12 IN1.0~1.3 RESERVED INPUT PORT -CN10 1~12 IN1.4~1.7 RESERVED INPUT PORT -