8REMKO PWLElectrical connections of the unitmust only be established by autho-rised specialists in compliance withthe applicable regulations of thelocal electricity supply company aswell as the VDE installation requi-rements relating to the unit.Connection of the unitsThe units are fitted with two-speed, 400V three-phase axialflow fans as standard.Speed selection takes place withappropriate control units (accesso-ry).Changes in direction take place viaa pole changing switch or specialcontrol unit (accessory).Motor protection is provided viaintegrated thermal contacts inconjunction with a suitable controlunit (accessory).Connection of the three-phasemotors to the respective controlunits takes place via the associatedelectrical wiring diagrams.ATTENTIONFailure to observe the pertinentrequirements, operating inst-ructions and electrical wiringdiagrams relating to the unitcan give rise to malfunctionswith consequential damage.This will invalidate the war-ranty!Connection of several unitsIf necessary, several units (alsodifferent sizes) can be operatedparallel via a control unit (accesso-ry).The total capacity of the con-nected units must not exceed themaximum switching capacity ofthe respective control unit.For thermal motor protection, thethermal contacts of all motorsmust be connected in series. Seeseparate wiring diagrams.Only one external control device(thermostat, day/night control,etc.) can always be connected percontrol unit.Terminals in the unitFuse protection in the supply tothe control unit must be in compli-ance with the applicable regulati-ons.The connections in the terminalbox must be connected to therespective control unit (accessory).Electrical connectionATTENTIONWhen the fan is stationary,the hydraulic supply must besimultaneously interrupted.ATTENTIONOnly suitably trained specialistsmay establish electrical con-nections.Connection to the local hy-draulic systemPrior to connection to the localhydraulic system, it must be en-sured that the respective capacityrequirements of the unit can beprovided at all times.■ Connection of the unit on thewater side must take place local-ly via suitable pipe fittings andshut-off valves in the flow andreturn.The use of compensators andautomatic venting devices isrecommended!■ The connection side at the topand the flow and return can beconnected as required.■ The pipe connection thread sizesis R 1“ internal thread.■ The fin heat exchangers must bethoroughly vented after installa-tion.Air cushions in the heat exchan-ger will reduce the heating orcooling capacity!Hydraulic connectionWater inletWater outletNOTEIn order to prevent damagedue to twisting of the con-necting pipes, a suitable toolmust be used to prevent theconnecting pipes rotatingwhile tightening the screwedconnections.5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22W2 U2V2 TK PE1 3 42U1V1 W1 TK PE PE N L13 2Kondensatpumpefür KühlbetriebCÖSNPotenzialfreier Alarmkontakt1KondensatpumpeKondensatpumpe