14Installations/ConnectionsBefore start the installation/connection, prepare the required devices and cables.Before starting the connection, turn the power of the devices including the camera and the PCoff or disconnect the AC adapters from the outlet.Step 1Fix an optional camera mount base onto thedesired place and mount the camera on it.When attaching an optional camera mountbase on the bottom of the camera, use theremoved screws to attach the camera mountbase.Otherwise, it may cause a drop or malfunc-tion.Recommended tightening torque: 0.39 N·m{4 kgf·cm}Important:• Method of installation may be differentdepending on the material of the placewhere the camera is to be installed.When installing on steel: Fix with boltsand nuts (M6 or M8).When installing on concrete: Fix withanchor bolts. (M6 or M8)• Do not use wood screws to fix the cam-era mounting bracket (option) since theyare not strong enough to support theweight of the camera and the bracket.Step 2Connect the monaural mini plug (ø3.5 mm) tothe monitor out connector (for adjustment) onthe rear of the camera. (Only when adjustingthe angular field of view)WV-NP244 is shown above.Important:The monitor out connector is providedonly for checking the adjustment theangular field of view on the video monitorwhen installing the camera or when serv-icing.It is not provided for recording/monitor-ing use.Step 3Connect the AC power cord (provided as astandard accessory) between the AC inlet ofthe camera and a 220V - 240V AC 50 Hz out-let.Notes:• Connect the power cord firmly.• The power cord should be long enoughfor panning and tilting.If the cable is too short, the power cordplug may be pulled out of the AC inletsocket of camera when the camera pansor tilts.Fixing screwTripod mount baseINITIAL SETGNDPOWER10BASE-T/100BASE-TXSDCARDMONITOR OUTEXT I/O1 2 3 4LINK ACTAC 24V IN : 1L – 2NDC 12V IN : ! – @Connect to the videomonitor, etc.