Wire ColorBrown 220 V to 240 V AC (L)Blue 220 V to 240 V AC (N)Green/Yellow To GND14Video output connectionThe video output connector is connected to the monitor orother system devices with a coaxial cable (locally pro-cured).The maximum extensible length is shown in the table.* When using 12 V DC power supply,the heater is unavailable.• To 24 V AC or 12 V DC powersupply (WV-CW384)• To 220 V to 240 V AC powersupply (WV-CW380)Video output cable(WV-CW384: Approx. 72 cmWV-CW380: Approx. 72 cm)Brown (Live)Blue (Neutral)Green/Yellow (GND) To GNDBNC connectorBNC connectorTo VIDEO INPower cord (WV-CW384: Approx. 72 cm,WV-CW380: Approx 165 cm)BNC connectorv Make a connectionRecommendedmaximum cablelengthRG-15/U(10C-2V)800RG-11/U(7C-2V)RG-6/U(5C-2V)RG-59/U(3C-2V)Type of coaxial cablem 600500250Wire Color 24 V AC 12 V DCBrown 24 V AC (L) PositiveBlue 24 V AC (N) NegativeGreen/Yellow To GND To GND• ONLY CONNECT THIS TO 24 V AC or 12 V DC CLASS2 POWER SUPPLY.• To prevent fire or electric shock hazard, the UL listedwire VW-1 style 1007 should be used for the cord forInput Terminals.• Do not use a transformer larger than 10 VA.Cord length and wire gauge24 V ACThe recommended cord length and copper wire size areshown in the table for reference.The voltage supplied to the camera should be between19.5 V AC and 28 V AC.Copper wiresize (AWG)Wire length(Approx.)#24(0.22 mm 2)20#22(0.33 mm2)30#20(0.52 mm 2)45#18(0.83 mm 2)75Recommended wire gauge for 24 V AC line.m12 V DCThe recommended resistance and copper wire size areshown in the table for reference.The voltage supplied to the camera should be between10.5 V DC and 16 V DC.Copper wiresize (AWG)Resistance (Ω/m)#24(0.22 mm 2)0.078#22(0.33 mm2)0.050#20(0.52 mm 2)0.03#18(0.83 mm 2)0.018Resistance of copper wire [at 20 °C]Power connectionCaution:• The following connections should be made by qualifiedservice personnel or system installers in accordancewith NEC 725-51.• Wire colors & functionsCamera power cordCautions:• Be sure to connect the GND (grounding) lead of thecamera and grounding terminal of the power supplywhen using a 24 V AC (WV-CW384) or 220 V to 240 VAC (WV-CW380) power source.• Shrinking the cord-entry seal is a onetime procedure.Do not shrink the cord-entry seal until it has been ascer-tained that unit is functioning."L", "R", "V A ", and "I" shall satisfy the inequality below.10.5 V DC ≤ VA - 2(R x I x L) ≤ 16 V DCL : Cord length (m)R : Resistance of copper wire (Ω/m)VA : DC output voltage of power supply unitI : DC current consumption (A). See the specification.Important:• When using 12 V DC power supply, the heater isunavailable.