PROBLEM PROBABLE CAUSE SOLUTION• The IP address of theControl Box fornetworking has beenforgotten.- • Connect a PC to the MNT port of theControl Box directly and start the WebMaintenance Console using the default IPaddress of the MNT port, and then confirmthe IP address assigned for the LAN port.For details of connecting the PC directly tothe Control Box, refer to "4.2 PCConnection".For details of checking current IP addressof the mother board, refer to "16.1Network Service—[1] IP Address/Ports—Basic Settings—LAN Setting—IPAddress" in the PC Programming Manual.6.1.3 Restarting the Control BoxIf the Control Box does not operate properly, restart the Control Box using Web Maintenance Console.Before restarting the Control Box, try the system feature again to confirm whether there definitely is aproblem or not.Note• With this procedure, data stored in memory is not cleared.• Be aware that restarting the Control Box with the System Mode Switch in the "SYSTEM INITIALIZE"position clears all data stored in the Control Box. Do not perform this operation unless you intend todelete all data from the Control Box.• When the Control Box is set to obtain IP addressing information automatically, and the Control Box isnot able to obtain appropriate IP addressing information from an external DHCP server, the ControlBox starts up with its default IP addresses and the STATUS indicator on the front of the cabinet turnsred. For the default IP addresses, refer to "4.3 Starting Web Maintenance Console".OperationIf the Control Box does not operate properly:1. Slide the System Mode Switch to the "NORMAL" position.6.1.3 Restarting the Control BoxInstallation Manual 59