6.23. Remove the stand brackets.1. Remove the plasma panel section from the servicing standand lay on a flat surface such as a table (covered), with theplasma panel surface facing downward.Spread a soft cloth or similar on the table for protection, sothe panel surface is not scratched.2. Remove the stand bracket (left, right) fastening screws (×4each) and remove the stand brackets (left, right).6.24. Remove the C4-Board1. Remove the flexible cables holder fastening screws (×8) and disconnct the flexible cables (CB8, CB9, CB10and CB11).2. Release the speaker cables from clampers.3. Disconnect the flexible cables (C41) and disconnect thecouplers (C42, C43 and C44).4. Remove the screws (×5 ) and remove the C4-Board.6.25. Remove the C5-Board1. Remove the flexible cables holder fastening screws (×8) and disconnect hte flexible cables (CB4, CB5, CB6and CB7).2. Release the speaker cables from clampers.3. Disconnect the flexible cables (C50, C51, C54 and C55)and disconnect the couplers (C52 and C53).4. Remove the screws (×5 ) and remove the C5-Board.6.26. Remove the C6-Board1. Remove the flexible cables holder fastening screws (×6) and disconnect the flexible cables (CB1, CB2 andCB3).2. Release the speaker cables from clampers.3. Disconnect the flexible cables (C60) and disconnect thecoupler (C61).4. Remove the screws (×5 ) and remove the C6-Board.14TH-50PM50U