Installation80 Installation Manual2.11 System Data Default Set2.11.1 System Data Default SetWhen the system does not operate properly after restarting, you can clear the programmingdata stored in the system. The system will restart with the default setting.First, try the operation by following step 4 in section 2.7.1 Starting the System for the FirstTime. If the system still does not operate properly, please follow the procedure below.1. Slide the system clear switch to the "CLEAR" position.2. Press the reset button (with a pointed tool, if necessary).3. While the power indicator starts flashing (within about 10 seconds), return the system clearswitch to the "NORMAL" position. If successfully executed, the DPTs should show thetime as 0:00.CAUTION• Before touching the system clear switch and reset button, put on a grounding strap.• After pressing the reset button, return the system clear switch to the "NORMAL" positionin step 3 while the power indicator is flashing. Otherwise, the system data will not becleared.• Even if you perform system data clear, OGM and voice message cannot be deleted. Todelete OGMs or voice messages, follow the steps described in 2.6.1 Built-in Voice Messageor 3.2.3 Recording Company Greeting Outgoing Messages in User Manual. To delete allvoice messages and OGMs at once, refer to programme [895] OGM and Voice MessageClear.• Feature Reference• System Data Default SetSystem Clear SwitchReset ButtonCLEARNORMAL