103.3 ScheduleNote:You need to have proper rights to implement the following operations. Please make sure theHDDs have been properly installed.After the system booted up, it is in default 24-hour regular mode. You can set record type and timein schedule interface.In the main menu, from Main menu->SETTING->STORAGE->SCHEDULE, you can go toschedule menu. See Figure 3-10. There are total six periods.Please note you need to go to Main menu->SETTING->SYSTEM->GENERAL->Holiday toset holiday date first, otherwise, there is no holiday setup item. Channel: Please select the channel number first. You can select “all” if you want to set forthe whole channels. : Sync connection icon. Select icon of several dates, all checked items can beedited or together. Now the icon is shown as . : Click it to delete a record type from one period. Record Type: Please check the box to select corresponding record type. There are fourtypes: Regular/MD (motion detect)/Alarm/MD&Alarm. Week day: There are eight options: ranges from Saturday to Sunday and all. Holiday: It is to set holiday setup. Please note you need to go to the General interface(Main Menu->SETTING->SYSTEM->GENERAL->Holiday) to add holiday first. Otherwise you cannot see this item. Pre-record: System can pre-record the video before the event occurs into the file. Thevalue ranges from 1 to 30 seconds depending on the bit stream. Redundancy: System supports redundancy backup function. It allows you backuprecorded file in two disks. You can highlight Redundancy button to activate this function.Please note, before enable this function, please set at least one HDD as redundant.(Main menu->SETTING->STORAGE->HDD MANAGER). Please note this function isnull if there is only one HDD. ANR: It is to save video to the SD card of the network camera in case the networkconnection fails. The value ranges from 0s~43200s. After the network connectionresumed, the system can get the video from the SD card and there is no risk of record loss. Period setup: Click button after one date or a holiday, you can see an interface shownas in Figure 3-11.There are four record types: regular, motion detection (MD), Alarm,MD & alarm. Please following the steps listed below to draw the period manually.