Intelligent controller (CZ-256ESMC2)Communication adaptor (CZ-CFUNC2)ON/OFF, operation mode setting, temperature setting, for fan speedsetting, air flow direction setting (when used without a remotecontroller), and remote controller local operation prohibition(prohibition 1, 2, 3, 4) can be doneA system without a remote controller is possible. Joint use with aremote controller or a system controller is also possibleUse of a schedule timer and holiday setting also can be doneProportional distribution of the air conditioning energy is possible.Including csv-file export via CF-card (supplementary accessory)NEW function: Pulse signal input from electric/gas consumption meterIn case of joint use with a wireless remote control system, there are limitations for the control mode. Please use only with“Permission” and “Prohibition 1”.Required to connect three or more linked wiring systems (indoor/outdoor operation lines) to the intelligent controllerAlso required for connection of P-AIMSLimitation contents for prohibited operationProhibition means limitation of the operation contents from the remotecontroller. It is also possible to change the prohibition items.Limitation contents (Limitations can be user defined)Individual There is no limitation for the operation of the remote controller.However, the contents will be changed to the contents of thecontroller operated last. (Last-pressed priority.)Prohibition 1 The remote controller cannot be used for ON/OFF. (All otheroperations are possible from the remote controller.)Prohibition 2 The remote controller cannot be used for ON/OFF, operationmode change and temperature setting. (All other operations arepossible from the remote controller.)Prohibition 3 The remote controller cannot be used for operation modechange and temperature setting. (All other operations arepossible from the remote controller.)Prohibition 4 The remote controller cannot be used for operation mode change.(All other operations are possible from the remote controller.)Note: Avoid joint use of the AMY system and the intelligent controller on the same indoor/ outdoor operation line.Max. 256 indoor units (4 systems x 64 units) can be controlled. In caseof three or more systems, a communication adapter CZ-CFUNC2 mustbe installed on the outsideOperation is possible as batch, in zone units, in tenant and in group unitsWebapplicationINTELLIGENTCONTROLLERCZ-256ESMC2DISPLAY SAMPLE Max. 4 links can be connected for the indoor/outdoor operation line = Max. 64 indoorunits x 4 (256 units) Max. 30 outdoor units x 4 (120 units)System signal x 4System signal x 4Linked system No. 1Linked system No. 2Linked system No. 3Linked system No. 4RS 485(Polarity shield wire)Communication adapterCZ-CFUNC2DimensionsH 240 x W 280 x D 138 mmPower supply AC 100 to 240 V (50 Hz), 20 W(separate power supply)I/O part Remote in put (voltage-freecontact): All ON/OFFRemote output (voltage-freecontact): All ON, All alarm (externalpower supply within DC 30 V, 0.5 A)Total wiring length: 1 km for each systemOnly for embedding in the panelDimensionsTouchpanelVRF ECOi