ConnectionOperation ModesOperation mode setting procedureIn the factory default state, connect the CCU to the unit and then set the operation mode.Operation in IP connectionOperation in serial connection1. Configure the IP address of the IPconnection device under [ROP IPSETTING] or [CAMERA IPSETTING] of the ROP menu or viathe Easy IP Setup Software.2. Configure the camera information toassign to each camera numberunder [CONNECT SETTING] of theROP menu or via the ROP SetupSoftware.3. Connect the CCU in IP connection,and start operations.1. Set the CCU connection toserial connection under[CONNECT SETTING] of theROP menu.2. Connect the CCU, and startoperations.Connect the CCU to the unit in the factory default state.NOTEDo not start Easy IP Setup Software and ROP Setup Software during operation. The ROP will be disconnected, which in turn maycause a problem with operation.Switching between serial connection and IP connectionSwitch between serial connection and IP connection via the [CONNECT SETTING] settings of the ROP menu or via the serial/LAN settingsof the ROP Setup Software.“35 CONNECT SETTING” (see page 114)“ROP Setup Software” (see page 132)When the settings are initialized, the operation mode returns to serial connection (factory default state).“INITIAL with NW” (see page 113)Serial connectionSerial connection with the CCU ispossible.IP connection is not possible.IP connectionIP connection with the CCU is possible.A serial connection can be used incombination with IP connections.Switch to IP connection *1Switch back to serial connection *2Factory default statePower ONWhen the settings are initialized, the operation mode returnsto serial connection (factory default state).*1: If an ROP configuration file that was saved to a memory card in IP connection is loaded in serial connection, the operation modebecomes IP connection.*2: If an ROP configuration file that was saved to a memory card in serial connection is loaded in IP connection, the operation modebecomes serial connection.- 16 -Connection