Instruction References6-8Example 5) When specifying the reading of cyclic communication registration node tableWhen the maximum registered node number is "0", only the value of [D] is updated and the values after [D+1] are notupdated.[S1]... "EIP" [S2]... "NODE" [D]...WR100ValueWR100 0 Max. registration node numberExample 6) When specifying the reading of cyclic communication normal node table[S1]... "EIP" [S2]... "NORMAL" [D]...WY100ValueWY100 7 Max. registration node numberWY101 0000 0000 0111 1111 Cyclic communication normal node table (Node nos. 1 to 9)Example 7) When specifying the reading of cyclic communication normal node tableWhen the maximum registered node number is "0", only the value of [D] is updated and the values after [D+1] are notupdated.[S1]... "EIP" [S2]... "NORMAL" [D]...WY100ValueWY100 0 Max. registration node numberExample 8) When specifying the reading of cyclic communication stop node table[S1]... "EIP" [S2]... "STOP" [D]...WR10ValueWR10 8 Max. registration node numberWR11 0000 0000 1111 1111 Cyclic communication stop node table (Node nos. 1 to 9)Example 9) When specifying the reading of cyclic communication stop node tableWhen the maximum registered node number is "0", only the value of [D] is updated and the values after [D+1] are notupdated.[S1]... "EIP" [S2]... "STOP" [D]...WR10ValueWR10 0 Max. registration node numberExample 10) When specifying the reading of cyclic communication abnormal node table[S1]... "EIP" [S2]... "ERR" [D]...WR100ValueWR100 5 Max. registration node numberWR101 0000 0000 0000 1000 Cyclic communication abnormal node table (Node nos. 1 to 9)