Mitsubishi Electric ERNT-ASLTX40 User Manual
Mitsubishi Electric Programmable ControllerRenewal ToolConversion AdapterModelERNT-ASLTX40ERNT-ASLTX80User’s Manual50CM-D180176-E(1612)HEAD OFFICE:Hulic KUDAN BLDG.1-13-5,KUDANKITA CHIYODA-KU,TOKYO 102-0073,JAPANNAGOYA ENGINEERING OFFICE:139 SHIMOYASHIKICHO-SHIMOYASHIKI,KASUGAI,AICHI 486-0906,JAPAN SAFETY PRECAUTIONS (Always read these precautions prior to use.)Before using this product, please read this manual carefully and pay full attention to safety to ensure thatthe product is used correctly.The precautions presented in this manual are concerned with this product only. For ProgrammableController system safety precautions, refer to the user’s manual of the MELSEC-L series CPU module tobe used.In this manual, the safety precautions are ranked as “WARNING” and “CAUTION.”Indicates that incorrect handling may cause hazardous conditions,resulting in death or severe injury.WARNINGIndicates that incorrect handling may cause hazardous conditions,resulting in medium or minor injury and/or property damage.CAUTIONNote that failure to observe the CAUTION level instructions may lead to a serious consequenceaccording to the circumstances. Always follow the precautions of both levels because they are importantto personal safety.Please keep this manual in an easy-to-access location for future reference, and be sure to provide themanual to the end user.[Precautions before using]CAUTION When making a switch from the MELSEC-AnS Series to the MELSEC-L Series, be sure toconsult user's manual supplied with individual module under the MELSEC-L Series to confirmdifferences in various aspects including performance, function, CPU input/output signals andbuffer memory addresses between the two series.[Installation Precautions]CAUTION Use the Conversion Adapter in the environmental conditions that are specified in the generalspecification. If the Products are used in any environment beyond the bounds of the generalspecification, electric shock, fire, malfunction, or damage to or degradation of the Products willresult. Do not directly touch any conductive parts of Conversion Adapter. Contact will causemalfunction or failure in the system. Fasten the Conversion Adapter and the Mounting Bracket securely with retaining screws, andtighten the screws by applying torque within specified limits. Loose screws can lead to thedropping of the Conversion Adapter or Mounting Bracket, possibly causing breakage thereof.Excessive tightness of the screws can lead to breakage of the screws, Conversion Adapter,Mounting Bracket, or MELSEC-L Series Module, possibly causing the dropping, shorting, andmalfunction thereof. Always check for correct match between MELSEC-L Series and the Conversion Adapter.Incorrect match can cause damage to the MELSEC-L Series Module. When installing the Conversion Adapter, take care not to get your hand snagged on theMounting Bracket or the like. Injury may result. When installing or removing the MELSEC-L Series Module complete with a ConverterAdapter, be sure to hold it with both hands. Dropping may lead to breakage.[Wiring Precautions]WARNING Before attempting to install the Unit or carry out the necessary wiring, make certain that theexternal power supply, used in the system, is shut off on all three phases. Failure to do so mayresult in electric shock or damage to the product . After installation and wiring, close the terminal block cover before turning on the module foroperation. Failure to do so may result in electric shock.[Wiring Precautions]CAUTION Carry out wiring for the Conversion Adapter correctly after checking the specification andterminal arrangement for the module used. Connecting a power supply with a different voltagerating or incorrect wiring may cause a fire or failure. Tighten the MELSEC-AnS Series terminal installation screws and terminal screw securely byapplying torque within the specified limits. Loose screws will cause short circuit, fire ormalfunction. Excessive tightening will damage the screws or the Conversion Adapter which inturn will cause dropping of parts, short circuit or malfunction. Use care to prevent foreign materials including cuttings and wiring debris from entering theConversion Adapter or the MELSEC-L Series Module. These will be cause for fire, failure ormalfunction.[Startup and Maintenance Precautions]WARNING Do not touch live terminals. There is a danger of electric shock or malfunction. Shut off the external power supply for the system in all phases before cleaning orretightening the terminal screws. Failure to do so may result in electric shock or cause theMELSEC-L Series module to fail or malfunction. Loose screws can lead to dropping,shorting, and malfunction. Excessive tightness of the screws can lead to breakage of thescrews, Conversion Adapter, Mounting Bracket, or MELSEC-L Series Module, possiblycausing the dropping, shorting, and malfunction thereof.CAUTION Do not modify the Conversion Adapter or take it apart. Doing so will cause failure,malfunction, personal injury, or fire. Do not drop the Conversion Adapter and Mounting Bracket or do not give a strong impactto it. This will cause damage.[Disposal Precautions]CAUTION When disposing of the product, treat it as industrial waste.EMC AND LOW VOLTAGE DIRECTIVESCompliance to the EMC Directive, which is one of the EU Directives, has been a legal obligationfor the products sold in European countries since 1996 as well as the Low Voltage Directivesince 1997.Manufacturers who recognize their products are compliant to the EMC and Low VoltageDirectives are required to declare that print a "CE mark" on their products.Authorized representative in EuropeAuthorized representative in Europe is shown below.Name: Mitsubishi Electric Europe B.V.Address: Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany1.OverviewThis manual describes specifications, handling and other information about the Conversion Adapter“ERNT-ASLTX40, ERNT-ASLTX80” available as Renewal Tools for the Mitsubishi ElectricProgrammable Controller.The Conversion Adapter is a product for effecting conversion to transcend difference in pinassignment between the MELSEC-AnS Series and the MELSEC-L Series.Before attempting to make a switch from MELSEC-AnS Series to MELSEC-L Series in yourinstallation, consult the user's manual supplied with individual module under the latter series to learnabout how they differ in various aspects including performance and function.Once you have opened the packaging, verify that it contains the following products.Product Shape QuantityConversion Adapter 1Mounting bracket 1Mounting bracket fixing screws (M3.5 x 6) 1Terminal block cover 1This manual - 12.General SpecificationsItem SpecificationsOperating ambienttemperature 0 to 55℃(Maximum surrounding air temperature 55℃)Storage ambienttemperature -25 to 75℃Operating ambienthumidity 5 to 95%RH,non-condensingStorage ambienthumidityVibrationresistanceCompliant withJIS B 3502andIEC 61131-2Frequency ConstantaccelerationHalfamplitude Sweep countUnderintermittentvibration5 to 8.4Hz - 3.5mm 10 times each inX, Y, Z directions8.4 to 150Hz 9.8m/s2 -Undercontinuousvibration5 to 8.4Hz - 1.75mm-8.4 to 150Hz 4.9m/s2 -Shock resistance Compliant with JIS B 3502 and IEC 61131-2(147 m/s2, 3 times each in 3 directions X, Y, Z)Operating atmosphere No corrosive gasesOperating altitude *1 0 to 2000mInstallation location Inside a control panelOvervoltage category *2 II or lessPollution degree *3 2*1:Do not use or store under pressure higher than the atmospheric pressure of altitude 0m.*2:This indicates the section of the power supply to which the equipment is assumed to be connected between thepublic electrical power distribution network and the machinery within premises.Category II applies to equipment for which electrical power is supplied from fixed facilities.*3:This index indicates the degree to which conductive material is generated in terms of the environment in whichthe equipment is used.Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity caused by condensingmust be expected occasionally.3.Product SpecificationsFor detail specifications which do not appear in the specification comparison charts contained herein,see the user's manual supplied with the MELSEC-L Series module you use. Those parts of thespecification that differ between the MELSEC-AnS Series and the MELSEC-L Series are where a switchfrom the first series to the second is subjected to specification-related restrictions. Check thespecification of the devices to be connected for more details.Furthermore, it is recommended to refer to the “Transition from MELSEC-AnS/QnAS (Small Type)Series to L Series Handbook (Fundamentals): L (NA)-08258ENG” issued by Mitsubishi Electric.3.1 ERNT-ASLTX40Conversion AdapterModelBefore replacementMELSEC-AnS SeriesModule ModelNo. ofInputpointsAfter replacementMELSEC-L SeriesModule ModelConversionAdapterWeight (g)No. ofmodulesERNT-ASLTX40A1SX40A1SX40-S1A1SX40-S216 LX40C6 1 75Internal circuit diagram of ERNT-ASLTX40A1SX40A1SX40-S1A1SX40-S2Terminal BlockLX40C6Terminal BlockTB2TB4TB6TB8TB10TB12TB14TB16TB18TB20TB1TB3TB5TB7TB9TB11TB13TB15TB17TB19TerminalNo.TB1TB2TB3TB5TB6TB7TB8TB9TB10TB11TB12TB13TB14TB15TB16TB17TB18TB19TB20TB4SignalNameX00X01X02X03X04X05X06X07COMX08X09X0AX0BX0CX0DX0EX0FOpenOpenCOMTerminalNo.TB1TB2TB3TB5TB6TB7TB8TB9TB10TB11TB12TB13TB14TB15TB16TB17TB18TB4SignalNameX00X01X02X03X04X05X06X07X08X09X0AX0BX0CX0DX0EX0FCOMOpenTB2TB4TB6TB8TB10TB12TB14TB16TB18TB1TB3TB5TB7TB9TB11TB13TB15TB1724VDC- +12VDC12VDC notavailable*1Precautions for wiringIf your system is set to run on a rated input voltage of 12VDC when you make a switch fromA1SX40 to LX40C6, it must be reset to run on 24VDC.< Specification Comparison >ModelSpecificationsMELSEC-AnS Series MELSEC-L SeriesA1SX40(Sink type)A1SX40-S1(Sink type)A1SX40-S2(Sink type)LX40C6(Positive common/Negative commonavailable)No. of input points 16 points 16 points 16 pointsIsolation method Photocoupler isolation Photocoupler isolation PhotocouplerisolationRated input voltage 12VDC 24VDC 24VDC 24VDCRated input current Approx.3mAApprox.7mA Approx.7mA 6mA TYP.ON voltage/ON current8VDC or higher/2mA or higher14VDC or higher/4mA or higher14VDC or higher/3.5mA or higher15VDC or higher/4mA or higherOFF voltage/OFF current4VDC or lower/1mA or lower6.5VDC or lower/1.7mA or lower8VDC or lower/2mA or lowerInput resistance Approx.3.3kΩ Approx.3.3kΩ 3.8kΩResponsetimeOFF→ON 10ms or less(24VDC)0.1ms or less(24VDC)10ms or less(24VDC) 1/5/10/20/70ms or lessON→OFF 10ms or less(24VDC)0.2ms or less(24VDC)10ms or less(24VDC) 1/5/10/20/70ms or lessInternal current consumption 50mA(TYP. all points ON)50mA(TYP. all points ON)90mA(TYP. all points ON)Wiring method for common 16 points, 1 common 16 points, 1 common 16 points, 1 commonExternal connection system 20-point terminal block 20-point terminal block 18-point terminal blockMake sure the section of the above table meets the specification of the machines andequipment connected to the MELSEC-L Series module.3.2 ERNT-ASLTX80Conversion AdapterModelBefore replacementMELSEC-AnS SeriesModule ModelNo. ofInputpointsAfter replacementMELSEC-L SeriesModule ModelConversionAdapterWeight (g)No. ofmodulesERNT-ASLTX80A1SX80A1SX80-S1A1SX80-S216 LX40C6 1 75Internal circuit diagram of ERNT-ASLTX80A1SX80A1SX80-S1A1SX80-S2Terminal BlockLX40C6Terminal BlockTB2TB4TB6TB8TB10TB12TB14TB16TB18TB20TB1TB3TB5TB7TB9TB11TB13TB15TB17TB19TerminalNo.TB1TB2TB3TB5TB6TB7TB8TB9TB10TB11TB12TB13TB14TB15TB16TB17TB18TB19TB20TB4SignalNameX00X01X02X03X04X05X06X07COMX08X09X0AX0BX0CX0DX0EX0FOpenOpenCOMTerminalNo.TB1TB2TB3TB5TB6TB7TB8TB9TB10TB11TB12TB13TB14TB15TB16TB17TB18TB4SignalNameX00X01X02X03X04X05X06X07X08X09X0AX0BX0CX0DX0EX0FCOMOpenTB2TB4TB6TB8TB10TB12TB14TB16TB18TB1TB3TB5TB7TB9TB11TB13TB15TB1724VDC- +-+12VDC12VDC notavailable*1Precautions for wiringIf your system is set to run on a rated input voltage of 12VDC when you make a switch fromA1SX80 to LX40C6, it must be reset to run on 24VDC.< Specification Comparison >ModelSpecificationsMELSEC-AnS Series MELSEC-L SeriesA1SX80(Sink/Sourceavailable)A1SX80-S1(Sink/Sourceavailable)A1SX80-S2(Sink/Sourceavailable)LX40C6(Positive common/Negative commonavailable)No. of input points 16 points 16 points 16 pointsIsolation method Photocoupler isolation Photocoupler isolation Photocoupler isolationRated input voltage 12VDC 24VDC 24VDC 24VDCRated input current Approx.3mAApprox.7mA Approx.7mA 6mA TYP.ON voltage/ON current8VDC or higher/2mA or higher17VDC or higher/5mA or higher13VDC or higher/3.5mA or higher15VDC or higher/4mA or higherOFF voltage/OFF current4VDC or lower/1mA or lower5VDC or lower/1.7mA or lower6VDC or lower/1.7mA or lower8VDC or lower/2mA or lowerInput resistance Approx.3.3kΩ Approx.3.3kΩ 3.8kΩResponsetimeOFF→ON 10ms or less(24VDC)0.4ms or less(24VDC)10ms or less(24VDC)1/5/10/20/70ms or lessON→OFF 10ms or less(24VDC)0.5ms or less(24VDC)10ms or less(24VDC)1/5/10/20/70ms or lessInternal current consumption 50mA(TYP. all points ON)50mA(TYP. all points ON)90mA(TYP. all points ON)Wiring method for common 16 points, 1 common 16 points, 1 common 16 points, 1 commonExternal connection system 20-point terminalblock20-point terminal block 18-point terminal blockMake sure the section of the above table meets the specification of the machines and equipmentconnected to the MELSEC-L Series module.*1*1 |
Related manuals for Mitsubishi Electric ERNT-ASLTX40
Mitsubishi Electric ERNT-ASLT62DA User Manual
Mitsubishi Electric ERNT-2JQ212S User Manual
Mitsubishi Electric ERNT-CQB051N User Manual
Mitsubishi Electric CC-Link User Manual
Mitsubishi Electric FX-485ADP User Manual
Mitsubishi Electric MAC-558IF-E Manual
Mitsubishi Electric 3DA-1 Owner's Manual
Mitsubishi Electric 3DA-1 Owner's Manual
Mitsubishi Electric PAC-SA88HA-E User & Installation Manual
Mitsubishi Electric LMAP03U Technical Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved