Installation Instructions Section 22-8 Part Number 000002688Electrical RequirementsIce Machine Head SectionRemote Condensing UnitIceMachineVoltagePhaseCycleAir-Cooled RemoteAir-Cooled Water CooledMaximumFuse/CircuitBreakerMinimumCircuitAmpsTotalCircuitAmpsMaximumFuse/CircuitBreakerMinimumCircuitAmpsMaximumFuse/CircuitBreakerMinimumCircuitAmpsQF400Before SerialNumber110638713115/1/60 15 NA 9.8 NA NA NA NA230/1/50 15 NA 4.2 NA NA NA NAQF400After SerialNumber110638713115/1/60 15 NA 6.9 NA NA NA NA230/1/50 15 NA 4.2 NA NA NA NAQC700115/1/60 30 18.9 NA NA NA 30 17.9230/1/50 20 8.8 NA NA NA 20 8.4230/1/60 15 8.7 NA NA NA 15 8.3QF800115/1/60 30 18.9 NA NA NA 30 17.9230/1/50 20 8.8 NA NA NA 20 8.4230/1/60 15 8.7 NA NA NA 15 8.3QF2300115/1/60 NA NA NA 15 5.5 NA NA230/1/50 NA NA NA NA NA NA NA230/1/60 NA NA NA NA NA NA NAInterconnecting wiring (115/60/1) is required between the ice machine and condensing unit to energize the contactor coil.Condensing Unit Voltage PhaseCycleMaximum Fuse/CircuitBreaker Minimum Circuit AmpsRFC2385 208-230/1/60 30 18.5208-230/3/60 20 12.8For United Kingdom OnlyAs the colours of the wires in the mains lead of the appliance may not correspond with the coloured markingsidentifying the terminals in your plug, proceed as follows:• The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked withthe letter E or by the earth ground symbol or coloured green or green and yellow.• The wire coloured blue must be connected to the terminal which is marked with the letter N or coloured black.• The wire coloured brown must be connected to the terminal which is marked with the letter L or coloured red.