FP 25/30/50 D / FP 10/20/30/50 ASafety InstructionsIssue: 05/2011 51 3 2 Lamphouse Hazards1 3 2 1 Broken GlassIn cold condition the xenon lamp has an inner pressure of about 8 to 10 bar (145 psi)and in hot condition of about 30 bar (435 psi). When a xenon lamp bursts, broken glasscan cause suffer injury to face, eyes and arteries. Therefore it is absolutely necessary towear protection with open lamphouse.DANGER OF ExPLOSIONS Never bypass a door switch.S Only work on open lamphouse and with xenon bulb with face protection (shield),neck protection and safety gloves which reach to the elbow.If the xenon lamp explodes you can suffer injury to face, eyes and arteries.S Dispose of the xenon bulb: Before removing xenon lamp put protective coveraround it, pack xenon bulb in original package and give it back to your supplier.S Only insert the new xenon bulb in protective cover. Remove cover after mountingthe xenon bulb.1 3 2 2 uv RadiationWARNING uv RADIATIONS Operate projector with a closed lamphouse only.S Use UV radiation eye and skin protection during adjustment of the lamp and conver-gence.S If you do some adjustments with an open lamphouse (look through visual hole), youhave to use visual protection which blocks the ultraviolet radiation.Never look into light of a xenon lamp without protective glasses!1 3 2 3 High voltageDANGERIgnite xenon lamp in closed lamphouse only.1 3 3 Mechanical DangerDANGERS Do not work around the machine with long loose hair, or loose clothing such asscarves or ties, they may get trapped in the drive mechanism and pull you in.S Only open shutter housing when projector is standing still with power disconnected.If the projector is running with covers open be careful and do not touch the rotatingshutter or other moving parts. Serious cuts can result.S Do not put your fingers between the film track and film pressure skate or betweensprockets and pad shoes.