FP 50 DIssue: 04/2011464 2 5 Ignition ButtonThe xenon lamp automatically ignites when pushing the start button on the projectoroperating panel.You can manually ignite the xenon lamp by pushing the ignition button.ATTENTIONDo not push this button for more than 0.5 seconds. The xenon bulb can be damagedif you push for a longer time. If the xenon lamp does not ignite after you have pushedthe button two to three times, the ignition unit or the rectifier or the xenon bulb probablyhave a defect.4 3 RectifierBy turning the hand wheel, the iron core in the coils will be moved and the intensity ofcurrent will be changed. The adjusted intensity of currents can be read on theammeter.X NOTEZ If you have an electronic rectifier the intensity of current is adjusted via apotentiometer switch.Z Detailed information about the rectifier can be found in the corresponding operatingmanual.Z Values for the intensity of currents, see chapter 6.4.16.