SP-5000M-CXP4 / SP-5000C-CXP4- 36 -7.5. Timed modeThis mode allows a single image frame to be captured with a preset exposure time by using theexternal trigger. Additional settings determine if the trigger pulse can be accepted during theexposure period.Primary settings to use this modeExposure Mode: TimedTrigger Mode: ONTrigger Overlap: OFF or ReadoutPixel Format t1 t2/t3 Link ConfigurationCXP6_X4 CXP3_X4 CXP6_X2 CXP3_X2 CXP6_X1 CXP3_X1Mono/BayerGR8bit10μs ormoret2 8.88 us 10 us 10 us 16.88 us 16.88 us 30.6 ust3 9L~10L 8L~9L 8L~9L 5L~6L 5L~6L 4L~5LMono/BayerGR10bitt2 8.88 us 11.72 us 11.72 us 20.3 us 20.3 us 37.5 ust3 9L~10L 7L~8L 7L~8L 4L~5L 4L~5L 3L~4LMono/BayerGR12bitt2 8.88 us 13.44 us 13.44 us 23.7 us 23.7 us 44.4 ust3 9L~10L 6L~7L 6L~7L 4L~5L 4L~5L 3L~4LRGB8bitt2 30.6 us 44.4 us 44.4 us 78.6 us 78.6 us 154 ust3 4L~5L 3L~4L 3L~4L 3L~4L 3L~4L 2L~3LFig.20 Overlap OFFTriggerCMOSExposureFVALExposureActive Exposure Periodt3t1t2